GE Appliances JVE40 Owner's Manual And Installation Instructions page 11

Vented range hoods
Table of Contents

Advertisement

Available languages

Available languages

Installation
Instructions
[_] FOR 3¼"x
:10" RECTANGLE DUCTED
DISCHARGE INSTALLATIONS:
Attach exhaust adaptor/damper
over knockout
opening with two exhaust adaptor screws. Hake sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.
Up to !" side-to-
side adjustment
ge
Exhaust adaptor/damper
(vertical discharge position
shown)
NOTE:The exhaust adaptor/dumper
can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme off-center
installations, one end of the duct connector may need to
be trimmed to clear the electrical cable clamp.
Ffl
MARK HOLES
Select the vent option that your installation will require
and proceed to that section:
A. Outside
top exhaust
(Vertical
duct-3¼"
x iO" Rectangular}
. Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
Hood mounting screws (4)
13¾"
IPA"
Wood shims
_
Electrical access
(recessed-bottom ll/16"
hole (in cabinet
Center
bottom)
cabinets only)
line
B. Outside
rear exhaust
(Horizontal
duct-3¼"
x lO" Rectangular}
. Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
Wood shims
(recessed-bottom cabinets only)
_-- 5½"
lPA"
Hood mounting
screws (4)
Center line
Cabinet
bottom
Electrical
access hole
(in wall)
C. RedrcuJating
(non-vented
ductless}
. Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
. Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.
11

Advertisement

Table of Contents
loading

Table of Contents