Installation instructions
ADVANCE
PLANNING
Ductwork Planning
* This hood may be vented vertically through
upper
cabinets, soffit or ceiling. A duct transition
piece is
supplied
for vertical exhaust. Use locally supplied
elbows to vent horizontally
through
the rear wall.
See page 13.
* Determine
the exact location
of the vent hood.
* Plan the route for venting exhaust
to the outdoors.
* Use the shortest and straightest
duct route possible.
For satisfactory
peffbrmance,
duct run should not
exceed
100 equivalent
length
for any duct
CO n figu raft O n s.
* Ref>r to "D u ct Fittings" c hart to comp u te the maximum
permissible
length
for duct
runs
to the outdoors.
* Use metal ductwork
on/y:
* A transition
piece for 7" round duct is supplied.
Use
7" round duct or you m W use 3-1/4" x 12" rectangular.
* Install a wall cap or roof cap with damper
at the
exterior
opening.
Order the wall or roof cap and
any transition
needed
in advance.
mt -JXDWl
Order kitJXDW1 if your installation requires horizontal
ducfing fi'om the top of the hood through the back _all mid:
*You have an 8 ft. ceiling and need to use aJXCH
Series Chimney Cove_; or
*You have a 12" cabinet or 12" soffit that the hood is to
be mounted
beneath.
This kit provides a duct transition
fiom 7" round to
3¼" x 10" rectangular
for through-the-wall
venting.
Wall Framing for Adequate
Support
* This vent hood is heax T. Adequate
structural
support
must be provided.
The hood must be secured
to
vertical studs in the wall. See page 14.
* We strongly recommend
that the vent hood with
duct cover be on site before final flaming and wall
finishing.
This will also help to accurately
locate the
duct_,vork and electrical
service.
DUCT FITTINGS
Follow
these
guidelines
for proper
duct sizing
in the
ducting
charts.
DUCTIN6 CHART- 30"and 36"Models
EquivalentLengthin FeetFor7" RoundDuct
Z
0
25
50
75
100
125
150
600
5OO
E
4OO
%0
200
7"Round 9 0 Elbow=14ft.
7" Roof C ap=39ft.
MAXIMUM DUCT LENGTH:
7" dia. duct, should not
exceed 100 equivalent
feet.
DECORATIVE
DUCT COVERS
A decorative
duct cover is available to fit both model
widths. The duct cover conceals the ductwor]< running
f)om the top of the hood to the ceiling or soffit. The
duct cover will fit 8 R. to 10 R. ceiling heights. See page
12 for derails.
POWER SUPPLY
IMPORTANT
- (Please read careflflly)
AWARNING'.
FOR PERSONAL SAFETY, THIS APPLIANCE
MU ST
BE PROPERIX
(;ROUNDED.
Remove house fl_se or open circuit breaker before
beginning
installation.
Do not use an extension
cord or adapter
plug with
this appliance.
Follow Nadonal
electrical
codes or
prevailing
local codes and ordinances.
Electrical
supply
This vent hood must be supplied
with 120V, 60Hz, and
connected
to an individual,
properly
grounded
branch
circuit, and protected
by a 15 or 20 amp circuit breaker
or dine delay fuse.
* Wiring must be 2 wire with ground.
* If the electrical supply does not meet the above
requirements,
call a licensed
electrician
before
proceeding.
* Route house wiring as close to the installation
location
as possible in the ceiling, soffit or wall.
See page 13 for details.
* Connect
the wiring to the house wiring in
accordance
with local codes.
Grounding
instructions
The grounding
conductor
must be connected
to a
grotmd metal, permanent
wiring system, or an
equipment-grounding
terminal or lead on the hood.
AWARNING:
co..ectio.
of the equipment-grounding
conductor
can result in a
risk of electric shock. Check with a qualified electrician
or service representative
if you are in doubt whether
the appliance
is properly
grounded.