Installation instructions
DUCT FiTTiNGS
Use
this
chart
to compute
maximum
peHnissible
lengths
for
duct
runs
to
O tltdoors.
Note: Do not exceedmaximumpermissibleequivalent
lengths!
Maximum duct length:
100 foot for vent hoods•
Flexible
ducting:
If flexible
metal
ducdng
is used,
all the equivalent
feet values
in
the table
should
be doubled.
The flexible
metal
duct should
be straight
and smooth
and
extended
as much
as possible.
Do NOT use flexible plastic ducting.
Note: Any homeventilation system,suchasa
ventilation hood,may interruptthe properflow of
combustionair andexhaustrequiredbyfireplaces,
gas furnaces,gas water heatersand other naturally
vented systems.To minimizethe chanceof interruption
of suchnaturallyventedsystems,follow the heating
equipmentmanufacturer'sguidelinesandsafety
standardssuchasthose publishedbyNFPAandASHRAE.
Toml
Equivalent
Quantity
Equivalent
Duct Piece
Dimensions
i,ength*
Used
Length
7" Round,
1 ft.
straight
(per foot
length)
• -1/4
x12"
1 ft.
straight
(per foot
length)
(_
7" 90 ° elbo_
] 4 ft.
7" 45 ° elbo_
9 ft.
• -1/4
x 12"
90 ° elbo_
]5 fL
• -1/4
x 12"
47)° elbo_
9 fL
:_
p*
• -I/4
x 12"
90 ° fiat elbo_
36 tL
_
7 p' I'Ot/lld
to
:_
p,
• -1/4
x 12"
transition
1 ft.
• -1/4
x12
t) / round
transition
1 ft.
7 pt I'OHlld
tO
•-1/4
x 12"
transition
90 ° elbo_
4 ft.
• -]/4
x12
t) / round
transition
90 ° elbo_
4 fL
7" P.o tu-Id
_all cap
with damper
28 fL (21 fL without
damper)
• -1/4
x 12"
_all cap _ith
damper
26 IL (19 IL _thout
damper)
7" Round
roof cap
39 fL
Round
roof vent
24 fL
This Hood Must Use 7" Round
Duct. It Can Transition To
3=1/4"× 12" Duct
Kit - JXDWI
Order ldtJXDW1
if your installation
requires
horizontal
ducdng
f?om the
top
of the
hood
through
the
back
wall
and:
* You
have
an
8 ft. ceiling
and
need
to
use
aJXCH
Series
Chimney
Covei;
or
* You
have
a 12"cabinet
or 12" soft:it
that
the
hood
is to be
mounted
beneath.
This
kit provides
a duct
transition
f}oIil
7** rotlild
to 31/4" X 10"
rectangular
fin through-the-wall
venting.
Using a smaller diameter duct size
will reduce performance
*Actual length of straight duct plus duct fitting equivalent.
Equivalent length of duct pieces are basedon actual
tests conducted by GE Evaluation Engineering and
reflect requirementsfor good venting performance
with any ventilation hood.
Total Duct Run
10