Performance Data Sheet - GE Model 20 Owner's Manual And Installation Instructions

Bottom freezer refrigerator
Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWater Filtration System
GSWF Cartridge
This system has been tested according to NSF/ANS142/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANS142/53.*
(100% safety factors built in for unmetered usage)
Parmneter
(_hlorin(
T & ()
Parti( ulate '_':
USEPA
MCL
Int]uent
Average
1.845 mg/I.
143,3.3.3 #imL
Effluent
Average
Maximmn
< 0.05mgiI.
0.05 mgiI
29.83 #imI.
140#imI.
% Reduction
Average
Minimmn
> _ 7 2( !'_
96.43%
Standard No. 42: Aesthetic Effects
hfl]uent
Ch'_enge
Concentration
2.0 mgiI.+
10%
at legist 10,000 pmticlt_simL
Standard
No. 53: HeMth
Effects
Influent Challenge
Effluent
99.98%
99.91%
Parmneter
USEPA
hrtluent
% Reduction
"[-u rbiditv
(X'sts
I.ead at pII 6.5
I.ead at pII 8.5
I.indane
Atrazine
Mha. Required
Reduction
> 50!_
> 85!_
Mill. Required
MCL
1 NTI ***
99.95!i P.c(luction
0.015 mgiL
0.015 mgiI
0.0002 mgiL
0.003 mgiL
Average
10.3 NTI 5***
2(_),(_)0 #iL
0.15 mgiL
0.14 mgiL
0.0216 mgiI.
0.008 mgiI.
Cozlceallraiion
1+1 NTI ***
Minimum
50,000 L
0.15 mgiI.+10!_i
0.15 mg!L+10%
0.002
mgiI.+10!_i
0.009
mgiI.+l
0!_
Average
0.106 NT[ 7
0
< 0.001 mg!L
0.001 mgiI.
< 0.00002 mgiL
< 0.002 mgiL
Maxilll
ilnl
0.14 NTI
0
< 0.tR)l mgiL
0.003 mgiI.
< 0.00002mgiL
< 0.1_)2mgiL
Average
98.97!;i
> 99.99%
> 99.33%
> 99.29%
99.07!;;
> 76.12rN
Mi*firnmn
Reduction
98.61 !:_
0.5 NTI
> 99.99%
> 99.95%
> 99.33%
0.010 mgiL
97.86!::i
0.010 mgiL
98.751:i
0.(;002
mgiI
> 66.67%
0.003 mg!L
* Tested using a flow ra te of O. 5 gpm; pressure of 60 psig; pH of 7.5 _+O, 5 ; temp, of 68 ° _+ 5°F (20 ° _+ 3°C)
** Measurement in Particles/ml. Particles used were 0,5-1 microns
* * * NTU=Nephelometric Turbidity units
Operating Specifications
• (_apa('ity:
certified
ti)r up to 750 gallons
(2,838 1); up to six months
• Pressure reqtfiremelm
40-120 psi (2.8-8.2
bar)
• TeI/lperattlre:
33-100°F
(0.6-38°C)
• How rate: 0.5 gpln
(1.9 lpln)
General Installation/Operation/Maintenance
Requirements
• Flush new cartridge
at full flow for .3 milmtes
to I)UI'ge, out trapped
air.
• Replace
cartridge
when
flow becolnes
too sh)w.
Special Notices
• h_stallation
ii_sti uctions,
parts
aim service
availability,
aim standard
warranty
are inchMed
with the product
when
shipped.
• This drinking
water system
mtlst be inaintained
according
to illalltllhCttlrer's
instructions,
ii_cltMing
replacenlent
of filter
cartridges.
• Do not use with water
that is microbioh)gically
tmsate
or of tmkI_own
quality
without
adequate
disilffection
betore
or
atier
the svsteln.
Svstelns
certified
tot
cvst reductioi_
inav be used on disintected
water
that inav contain
filterable
cysts.
• The COlmtndlmnts
or other
substances
relnoved
or red(teed
bv this water
treatn/ent
svsteln
are not necessarily
in wmr
water.
• Check
tor conq)liance
with the state aim local
laws aim regtdations.
• Note
that while the testing
was pertimned
trader
standard
laboratory
conditioi_s,
actual
perfornmnce
inay wtrv. Svstelns
inust be installed
aim operated
in accordance
with inanuthcturer's
recomlnelMed
procedures
and
gtfidelines.
System tested and certified
bv NSF International
against Start(lard 42 for tile reduction
of
chlorine,
taste and odol; par{iculat_
Class I and Standard
53 ti)l- the retluction
of cyst,
lead, I.indane,
Atrazine
and mrbidilv.
ManuL,ctured
fin-: General
Electric Compan 5 I.oui_ville, EY 40225
4/

Advertisement

Table of Contents
loading

This manual is also suitable for:

Model 222220

Table of Contents