Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste - LYNXRPK-2 - Wireless Self-Contained Security System Installation And Setup Manual page 38

Installation guide
Table of Contents

Advertisement

LYNXR-2 Series Installation and Setup Guide
✻ 56 Enhanced Zone Programming Mode
l
E
Loop Number or Loop and
Serial Number
(if using RF Learning)
1-4 = loop number for the zone of the
transmitter being entered.
0 + [✻] = continue to DELETE ZONE
PARAMETERS CONFIRMATION
prompt (F)
[✻] = continue to the ENROLL MODE prompt
(1A) if not entered, or VOICE
DESCRIPTOR prompt if already entered
[#] = return to previous prompt
F
Delete Zone Parameters
Confirmation
0 = discard the delete request
1 = confirm requested delete
Note: If 00 was entered as a zone type in
prompt (b), 00 will be retained and
system will advance to prompt (1C).
This prompt can be used to enroll loop number and serial number via RF transmission
or the loop number can be enrolled manually. If using the RF Learning Mode, there is
no need to manually enter a loop number. Proceed directly to RF Learning
Notes: (1) BR type devices cannot be enrolled by using UR or RF type. Likewise, UR or
RF type devices cannot be enrolled by using a BR type device. There is a 52-
second time-out for RF enrolling. At the end of the time-out, the system returns
to the INPUT TYPE prompt (d). If enrolled, loop number and "L" are displayed.
(2) Once encrypted (high-security) devices have been enrolled they must be
activated. Refer to the device's Installation Instructions to activate the High-
Security Mode.
RF Learning - Two (2) transmissions (2 key depressions) at least 5 seconds apart
will be required for BR type devices (device type 5). Two beeps will sound after the
second transmission, confirming that the loop number and serial number have been
learned.
For all other device types, four (4) transmissions are required (fault, restore and fault,
restore). A single beep will sound after the second transmission confirming that the
loop and serial number have been captured. Following the fourth transmission the
system will confirm that the loop number and serial number have been learned and
announce the Voice Descriptor for the zone, if it is programmed, followed by two
beeps.
Press [✻] to continue.
Manual Entry - Enter the desired loop number and press [✻] to continue (see the
transmitter's Installation Instructions for specific loop designations).
Note: The loop number can be changed even if the zone has already been entered.
Care should be taken when using this feature as it has the capability to make
zones inoperable by creating a mismatch of a working serial number/loop number
combination. This should be re-confirmed if the loop number is changed.
"L" indicates that the zone's serial number has already been enrolled.
This function deletes either the serial number or all zone information that is
programmed for the zone.
If "00" was entered in the zone type, the confirmation of the delete request will delete
all information associated with the zone currently being programmed.
If "0" was entered in the loop number, the confirmation of the delete request will
delete the serial number of the zone currently being programmed.