Honeywell LYNXRPK-2 - Wireless Self-Contained Security Syste - LYNXRPK-2 - Wireless Self-Contained Security System Installation And Setup Manual page 23

Installation guide
Table of Contents

Advertisement

✻35
Entry Delay 01
LYNXR-2 SELECTIONS
00-99 = entry delay time in seconds.
LYNXR-2SIA SELECTIONS
Entries from 30-99
Entered Value
Delay in Seconds
30-96
30-96
97
120
98
180
99
240
✻36
Entry Delay 02
LYNXR-2 SELECTIONS
00-99 = entry delay time in seconds.
LYNXR-2SIA SELECTIONS
Entries from 30-99
Entered Value
Delay in Seconds
30-96
30-96
97
120
98
180
99
240
AUDIBLE EXIT WARNING/QUICK EXIT (
Note: This field is not available on the LYNXR-2SIA control.
✻37
Audible Exit Warning/Quick Exit
Exit Warning
0 = no exit warning sound
1 = provide exit warning sound
when armed AWAY
✻38
Confirmation of Arming Ding
LYNXR-2 SELECTIONS
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button or RF
keypad only
LYNXR-2SIA SELECTIONS
0 = no arming confirmation ding after arming system by
LYNXR keypad or RF keypad
1 = arming confirmation ding after arming system by LYNXR
keypad or RF keypad
2 = arming confirmation ding after arming from RF keypad
only
The system will wait the time entered before sounding alarm
upon entering if system is not disarmed.
UL installations: must be set for a maximum of 45 seconds
Note: The LYNXR-2SIA control validates the data entered in this field. If
SIA The Entry delay must be set to a minimum of 30 seconds. The
The system will wait the time entered before sounding alarm
upon entering if the system is not disarmed.
UL installations: must be set for a maximum of 45 seconds
Note: The LYNXR-2SIA control validates the data entered in this field. If
SIA The Entry delay must be set to a minimum of 30 seconds. The
37)
Exit Warning: Sound consists of slow continuous beeps until
last 5 seconds, when it changes to fast beeps. The warning
Quick Exit
sound will end at the termination of exit delay.
0 = no quick exit
Quick Exit: If enabled, user can restart the exit delay time
1 = allow quick exit
after arming in STAY mode by entering the user code and
pressing the STAY key, or by pressing the STAY key if Quick
Arm is enabled. This avoids having the user disarm then re-
arm the system after allowing someone to enter or exit
LYNXR-2
Confirmation of arming is provided by a 1/2 second external
sounder "ding" that sounds when closing report is sent, or at
the end of exit delay.
If Option 2 is selected the external sounder "ding" occurs
immediately after the system receives the RF transmission.
LYNXR-2SIA
Confirmation of arming is provided by a 1/2 second external
sounder "ding" .The confirmation ding only sounds when
LYNX is Armed Away or disarmed after being Armed Away.
If Option 1 is selected, confirmation of arming is provided by a
1/2 second sounder "ding" that sounds when closing report is
sent, or at the end of exit delay.
If Option 2 is selected the external sounder "ding" occurs
immediately after arming from an RF keypad.
Note: If LYNXR-2SIA is armed by RF button (key fob), a confirmation
LYNXR-2 Series Installation and Setup Guide
Data Field Descriptions
the selection is not valid the control will emit a single long beep
indicating that the selection has been rejected. The control
replaces the selection with the default value "30", which is
displayed on the keypad, and advances to the next field.
sum of entry delay 1 entered in Field ✻35 and the burglary abort
window entered in ✻50 should not exceed 1 minute.
the selection is not valid the control will emit a single long beep
indicating that the selection has been rejected. The control
replaces the selection with the default value "30", which is
displayed on the keypad, and advances to the next field.
sum of entry delay 2 entered in Field ✻36 and the burglary abort
window entered in ✻50 should not exceed 1 minute.
ding occurs immediately after arming regardless of field *38
settings. If LYNX is disarmed by RF button (key fob), additional
disarming confirmation ding is provided. The ding occurs
immediately after disarming and is longer than arming
confirmation ding.
- 23 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lynxr-2 series

Table of Contents