Configuring A Lun-Based Zone; Assigning Luns To Storage Subsystems - Cisco DS-X9530-SF1-K9 - Supervisor-1 Module - Control Processor Configuration Manual

Mds 9000 family
Table of Contents

Advertisement

About LUN Zoning
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Figure 19-6

Configuring a LUN-Based Zone

To configure a LUN-based zone, follow these steps:
Command
Step 1
switch# config t
switch(config)#
Step 2
switch(config)# zone name LunSample vsan 2
switch(config-zone)#
Step 3
switch(config-zone)# member pwwn
10:00:00:23:45:67:89:ab lun 0x64
switch(config-zone)# member fcid 0x12465
lun 0x64

Assigning LUNs to Storage Subsystems

LUN masking and mapping restricts server access to specific LUNs. If LUN masking is enabled on a
storage subsystem and if you want to perform additional LUN zoning in a Cisco MDS 9000 Family
switch, obtain the LUN number for each host bus adapter (HBA) from the storage subsystem and then
configure the LUN-based zone procedure provided in the
page
Refer to the relevant user manuals to obtain the LUN number for each HBA.
Note
If you make any errors when configuring this scenario, you are prone to loose data.
Caution
Cisco MDS 9000 Family Configuration Guide
19-18
LUN Zoning Access
H1
Zone 1
Zone 2
Zone 2
H2
19-18.
Fabric
Purpose
Enters configuration mode.
Configures a zone called LunSample for the
specified VSAN (vsan 2).
Configures a zone member based on the specified
pWWN and LUN value.
Note
Configures a zone member based on the FC ID and
LUN value.
"Configuring a LUN-Based Zone" section on
Chapter 19
Configuring and Managing Zones
S1
LUN 0
LUN 1
LUN 2
S1
LUN 3
LUN 0
LUN 1
LUN 2
S2
LUN 3
The CLI interprets the LUN identifier value
as a hexadecimal value whether or not the
0x prefix is included. For example, 64 in
hex formation corresponds to 100 in
decimal format.
OL-6973-03, Cisco MDS SAN-OS Release 2.x

Advertisement

Table of Contents
loading