How To Use Keypad; Name And Content Of Each Part - Hitachi WJ Series User Manual

Table of Contents

Advertisement

Chapter 7

7.1 How to Use Keypad

7.1.1

Name and Content of Each Part

 The names and descriptions of the parts of Keypad are shown below.
The LEDs at the top of the display are
shown below in order from the right.
(1) Power LED [PWR] (green)
(2) Current monitor LED [A] (green)
(3) Frequency monitor LED [Hz] (green)
(4) Program LED [PRG] (green)
(5) Alarm LED [AL] (red)
(6) Running LED [RUN] (green)
(7) Negative LED [-] (red)
(8) Display (5-digit LED)
(15) RJ45 connector
(16) USB connector
(1) Power LED [PWR]
(2) Current monitor LED [A] ●(green)
(3) Frequency monitor LED [Hz]
(4) Program LED [PRG]
(5) Alarm LED [AL]
(6) Running LED [RUN] ●(green)
(7) Negative LED [-] ●(red)
(8) Display (5-digit LED)
(9) RUN command indicator LED
(10) RUN key
(11) STOP/RESET key
Name
(green)
(green)
(green)
(red)
(green)
Keypad and Related Functions
Lights up (green) while the inverter is powered on.
Lights up (green) when the displayed data is current.
Lights up (green) when the displayed data is frequency.
Lights up (green) when the display indicates the data (set
value) that can be changed.
Blinks when the set value is inconsistent. Refer to "15.3
Troubleshooting for Warning Functions Related Error".
Lights up (red) when the inverter trips. Refer to "Chapter 15
Tips/FAQ/Troubleshooting" for more information about
tripping.
Lights up (green) when the inverter is running (since it lights
up under the OR conditions of [With RUN command] and
[While inverter outputs], it also lights up during deceleration
after RUN command is turned off).
Lights up (red) when the data on the display is negative.
Displays data (red) such as various parameters and
frequency setting values.
Lights up (green) when RUN command source is "Keypad".
(Keypad's RUN key is enabled.)
Even if RUN command source is Keypad's RUN key, this
LED blinks when RUN key is pressed while operation
cannot be performed due to some function. For details,
refer to "15.3 Troubleshooting for Warning Functions
Related Error ".
Operates the inverter. However, it is valid when RUN
command source is "Keypad". The operating direction is set
in "RUN key command rotation direction [F004]".
Decelerates and stops the inverter. By "STOP/RESET-key
enable [b087]", operation stop by this key can be
switched enabled/disabled.
If the inverter is tripping, it will reset (return from trip
state).
7-1-1
(9) RUN command
indicator LED (green)
(10) RUN key
(11) STOP/RESET key
(12) Esc key
(13) SET key (center)
(14) JOG dial
Up
(Clockwise rotation)
Down
(Counterclockwise
rotation)
Description