AEG EWUD040B8B User Manual page 34

Table of Contents

Advertisement

Available languages
  • EN

Available languages

34
www.electrolux.com
Problem
Too much vibration.
The appliance is noisy.
Water flows on the rear
plate of the appliance.
Water flows inside the
wine cabinet.
Water flows inside the
wine cabinet.
The temperature in the
wine cabinet is too low or
too high.
If the advice does not lead to
the desired result, call the
nearest Authorised Service
Centre.
9.2 Replacing the lamp
The appliance is equipped with a longlife
LED interior light.
Only service is allowed to replace the
lighting device. Contact your Authorised
Service Centre.
Possible cause
The light button is not op‐
erating.
The appliance is not sup‐
ported properly.
The appliance is not sup‐
ported properly.
During the automatic de‐
frosting process, frost
melts on the rear plate.
The appliance drains are
clogged.
Products prevent that
water flows into the water
collector.
The temperature regula‐
tor is not set correctly.
The door is not closed
correctly.
9.3 Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer
to the "Installation" chapter.
3. If necessary, replace the defective
door gaskets. Contact the Authorised
Service Centre.
Solution
Contact the Authorised Serv‐
ice Centre.
Check if the appliance
stands stable.
Check if the appliance
stands stable.
This is correct.
Clean the appliance drain
holes Refer to the "Cleaning
the drain" section.
Make sure that products do
not touch the rear plate.
Set a higher or lower tem‐
perature.
Refer to the "Closing the
door" section.