Text
ZERO PRICE
TEFRA
TAXABLE1
TAXABLE2
TAXABLE3
TAXABLE4
GR.DISC.
GR.DISC.
GR.DISC.
CVM1 CTRL CHAR.
CVM2 CTRL CHAR.
ASSOCIATED DEPT.
DATA ENT.JOB#
EXPIRY DATE
REVENUE NO.
I I I I I Range PLU programming
The following parameters of PLU can be programmed by a range.
The range data of PLUs is required at the beginning.
PLU code: max. 6 digits (1 to 999999)
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [2 ITEM SETUP] button to display the menu, and touch the [1 PLU/UPC] button to display
the detail menu.
(3) Touch the [2 RANGE PLU] button to program PLUs with assigning PLU range, and enter the following
range data and touch the [ENTER] key.
Text
START CODE
END CODE
OPERATION
(4) Touch the required programming item, and enter or select each parameter and touch the [ENTER] key.
Repeat this step (4) satisfactorily.
(5) To terminate the programming, touch the [EXIT] key.
162
ALLOWED: Allows a zero-price entry.
DISALLOWED: Disallows a zero-price entry.
YES: TEFRA report
NO:
Non-TEFRA report
YES: Tax 1 taxable
NO:
Tax 1 non-taxable
YES: Tax 2 taxable
NO:
Tax 2 non-taxable
YES: Tax 3 taxable
NO:
Tax 3 non-taxable
YES: Tax 4 taxable
NO:
Tax 4 non-taxable
Group discount grouping max. 2 digits (1 to 99/0)
Group discount grouping max. 2 digits (1 to 99/0)
Group discount grouping max. 2 digits (1 to 99/0)
CVM (Color Video Monitor) 1 control character (0 thru 255)
CVM (Color Video Monitor) 2 control character (0 thru 255)
Department number to be associated with the entered PLU. 2 digits ((1 to 99)/0)
Key data entry no. max. 2 digits (1 to 99/0)
(1 thru 99 : Data entry compulsory)/(0 : Data entry inhibit)
Expiry date max. 6 digits (000000: 00/00/2000)
Revenue center no. (1 thru 9)
(2 ITEM SETUP
Start code of the range max. 6 digits (000000-999999)
End code of the range max. 6 digits (000000-999999)
Type for the operation
DEL: Delete
MAINTENANCE: Maintenance
NEW&MAINTENANCE: New create and maintenance
Parameter