W
iring diagram
Fig. D-5
Wiring on Motor Housing
Be sure to route all of the Lead wires inside of the ribs a) to d) as drawn below
to prevent the wires from being pinched between Motor housing and Rear cover.
Put Terminal block/ Closed-end splice in place as drawn below.
Bottom View
Switch
Terminal
block
rib (b)
Fix Field lead wire (red)
in these two grooves.
Switch
Closed end
splice
rib (b)
Fix Field lead wire (red)
in these two grooves.
When Terminal block is used
rib (a)
Switch lever
Noise
suppressor
rib (c)
rib (d)
When Closed end splice is used
rib (a)
Switch lever
Noise
suppressor
rib (c)
rib (d)
Left Side View
rib (a)
Terminal
block
rib (b)
rib (a)
Closed end
splice
rib (b)
P 12/ 13