H355R: Fast-response, low-profile heat detector with rate-of-rise
Whitney Even on 06/22/2022
option.
H355HT: Fast-response, low-profile heat detector that activates at
190°F/88°C.
AD355: Low-profile, intelligent, "Adapt" multi-sensor detector
(B350LP base included).
B200SR: Addressable sounder base.
BEAM355: Intelligent beam smoke detector.
BEAM355S: Intelligent beam smoke detector with integral sensitiv-
ity test.
D355PL: InnovairFlex low-flow non-relay duct-detector housing;
includes SD355R.
DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order
SD355R/SD365R separately.)
DNRW: InnovairFlex low-flow non-relay duct-detector housing, with
NEMA-4 rating. Watertight. (Order SD355R/SD365R separately.)
Addressable Modules
MMF-300: Addressable Monitor Module for one zone of normally-
open dry-contact initiating devices. Mounts in standard 4.0" (10.16
cm.) box. Includes plastic cover plate and end-of-line resistor. Mod-
ule may be configured for either a Style B (Class B) or Style D (Class
A) IDC.
MDF-300: Dual Monitor Module. Same as MMF-300 except it pro-
vides two Style B (Class B) only IDCs.
MMF-301: Miniature version of MMF-300. Excludes LED and Style
D option. Connects with wire pigtails. May mount in device backbox.
MMF-302: Similar to MMF-300. Addressable Monitor Module for one
zone of conventional two-wire detectors. Requires resettable 24
VDC power. Refer to the Device Compatibility Document for listed
compatible devices and quantity limitation.
CMF-300: Addressable Control Module for one Style Y/Z (Class B/
A) zone of supervised polarized Notification Appliances. Mounts
directly to a 4.0" (10.16 cm.) electrical box. NAC option requires
external 24 VDC to power notification appliances.
CRF-300: Addressable relay module containing two isolated sets of
Form-C contacts, which operate as a DPDT switch. Mounts directly
to a 4.0" (10.16 cm.) box, surface mount using the SMB500.
BG-12LX: Addressable manual pull station with interface module
mounted inside.
I300: This module isolates the SLC loop from short circuit conditions
(required for Style 6 or 7 operation).
ISO-6: Six-fault isolator module. Mount one or two modules in a BB-
2F cabinet (optional). Mount up to six modules on a CHS-6 chassis
in a BB-6F cabinet.
SMB500: Used to mount all modules except the MMF-301 and
M301.
MMF-300-10: Ten-input monitor module. Mount one or two modules
in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6
chassis in a BB-6F cabinet.
MMF-302-6: Six-zone interface module. Mount one or two modules
in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6
chassis in a BB-6F cabinet.
CMF-300-6: Six-circuit supervised control module. Mount one or two
modules in a BB-2F cabinet (optional). Mount up to six modules on a
CHS-6 chassis in a BB-6F cabinet.
CRF-300-6: Six-relay control module (Form-C relays). Mount one or
two modules in a BB-2F cabinet (optional). Mount up to six modules
on a CHS-6 chassis in a BB-6F cabinet.
SWIFT Wireless Devices
W-GATE: LiteSpeed Wireless Gateway
W-SD355: LiteSpeed intelligent, wireless photo detector.
W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat
detector.
W-SD355T: intelligent wireless photo/heat detector.
W-H355: LiteSpeed intelligent wireless fixed-temperature (135°)
heat detector.
W-MMF: LiteSpeed Intelligent wireless monitor module.
W-CRF: LiteSpeed Intelligent wireless relay module.
W-BG12LX: LiteSpeed Intelligent wireless pull station.
WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV
bases.
W-USB: Wireless USB radio/antenna dongle that plugs into the
USB port of a PC running SWIFT Tools.
SWIFT Tools: Programming and diagnostic utility for the Wireless
Gateway and devices. Available for download from firelite.com.
NOTE: For more information on Compatible Addressable Devices for
use with the ES-200X, see the following data sheets (document num-
bers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 (DF-
52386), BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-
52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series
(DF-52385), I300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/
MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-
52356), SD355/SD355T (DF-52384), and SLC Wiring Manual (51309).
NOTE: Legacy 300 Series detection devices such as the CP300/CP350,
SD300(T)/SD350(T) and older modules such as the M300, M301, M302,
C304, and BG-10LX are not compatible with LiteSpeed polling. If the
SLC contains one of these devices, polling must be set for standard
CLIP protocol. Please consult factory for further information on previous
300 Series devices.
ADDRESSABLE DEVICE ACCESSORIES
End-of-Line Resistor Assembly (R-47K and R-3.9K): The
47k ohm assembly supervises the MMF-300, MDF-300, MMF-301,
and CMF-300 module circuits. The 3.9k ohm assembly supervises
the MMF-302 module circuit. These resistors are included with each
module.
Power Supervision Relay: Supervises the power to 4-wire smoke
detectors and notification appliances.
Wiring Requirements
While shielded wire is not required, it is recommended that all SLC
wiring be twisted-pair to minimize the effects of electrical interfer-
ence. Refer to the panel manual for wiring details.