Set the calibration area, and the calibration area shall be drawn in the same horizontal
plane.
1.
Select Setting > Event Manage > Deep IVS > Global Setup.
2.
Select the preset to set the global setup function.
The preset must have already been configured with a smart plan.
Click Add Calibration Area, and then draw the calibration area on the monitoring
screen.
Click Remove Calibration Area to delete the drawn calibration area.
3.
Select to draw Vertical ruler or Horizontal ruler.
4.
Set the length of the ruler to be drawn in the actual environment.
5.
Click Add Rulers and draw the ruler on the monitoring screen.
Drawing vertical rulers: The bottom of the three vertical rulers shall be on the same
horizontal surface, and you shall select three reference objects with fixed height and
located in triangular distribution, such as vehicles parked on the road or street light
poles. The best way is to arrange a person to stand at those three positions, and
draw the line respectively.
Drawing horizontal rulers: Select reference objects with known length such as the
signs on the road, or you can measure their length on site.
Click Remover Rulers to delete the drawn ruler.
6.
Select the type of calibration verification from Weight Verification and Height
Verification, and then click Calibration Validation to draw a straight line on the
monitoring screen to display the corresponding actual length.
After the ruler setting is completed, verify the setting parameters by using the
verification tool. If the difference is too big, you need to adjust the parameters until it
meets the requirement.
7.
Configure parameters as needed.
Parameter
Description
Set it to 1–10, and the default value is 5. The greater the value is, the easier the
Sensitivity
lower contrast targets and small targets are to be triggered, and the higher the
false detection rate.
Add Detect
Click this button to draw a detection area where the Device will detect objects.
Region
Add Exclude
Click this button to draw an exclusion area, which will not be included in the
Region
detection range.
8.
Click Save.