Cisco 7513-MX Overview

Cisco 7513-MX System Specifications

Table 1-5
Table 1-5
Cisco 7513-MX Specifications
Description
Backplane
Dimensions
(H x W x D)
Weight
Power dissipation
Heat dissipation
AC-input voltage
Frequency
1
AC-input cable
AC-input voltage
and current
DC-input voltage
and current
DC-input cable
Power distribution
Airflow/noise level
Temperature
Relative humidity
Software requirement
Agency approvals
1. The Cisco 7513-MX requires a minimum of 20A service with a 20A receptacle at the power source. The power cable supplied with the Cisco 7513-MX
uses a 20A male plug.
Cisco 7500 Series Installation and Configuration Guide
1-24
lists the specifications for the Cisco 7513-MX system.
Specification
Two 1.0677-Gbps CyBuses: 11 interface processor slots, 2 RSP slots
33.75 x 17.5 x 22 in. (85.73 x 44.45 x 55.88 cm)
Chassis width including rack-mount flanges is 18.93 in. (48.1 cm)
Chassis depth including power cables and cable-management bracket is 24 in. (60.96 cm)
Chassis with blower module: 75 lb (34.02 kg)
Chassis with blower module and 1 power supply: 100 lb (45.36 kg)
Chassis with blower module and 2 power supplies: 125 lb (56.7 kg)
Chassis with blower module, 2 power supplies, and all slots filled: ~160 lb (72.58 kg),
each processor module weighs ~2.5 lb (1.13 kg)
1600W with a maximum configuration and 1 AC-input power supply
1600W with a maximum configuration and 1 DC-input power supply
1700W nominal with a maximum configuration and either 2 AC-input or 2 DC-input power
supplies
1600W (5461 Btu/hr)
100 to 240 VAC
50/60 Hz
12 AWG, with 3 leads, an IEC-320 plug on the router end, and a country-dependent plug on the
power source end
100 VAC at 16 amps (A) maximum, wide input with power factor corrector (PFC)
240 VAC at 7A maximum
–48 VDC nominal at 35A in North America (–60 VDC at 35A in the European Union)
8 AWG (recommended minimum), with 3 leads and rated for at least 194°F (90°C) (you supply the
cable)
+5.2 VDC @ 75A, +12 VDC @ 15A, –12 VDC @ 3A, +24 VDC @ 5A
Bottom to top through chassis by variable-speed blower (62 to 70 dBA)
32 to 104°F (0 to 40°C), operating; –4 to 149°F (–20 to 65°C), nonoperating
10 to 90%, noncondensing
RSP2 – Cisco IOS Release 10.3(6) or a later release of 10.3
RSP4/4+ – Cisco IOS Release 11.1(8)CA or a later release of 11.1
RSP8 – Cisco IOS Release 12.0(9)S or a later release of 12.0 S
RSP16 – Cisco IOS Release 12.1(12)E and later and Cisco IOS 12.0(21.02)S and later
Safety: UL 1950, CSA 22.2-950, EN60950, EN41003, TS001, AS/NZS 3260
EMI: FCC Class A, EN60555-2, EN55022 Class B, VDE 0878 Part 3, 30 Class B
Immunity: EN55101/2 (ESD), EN55101/3 (RFI), EN55101/4 (Burst), EN55101/5 (Surge),
EN55101/6 (Conducted), IEC77B (AC Disturbance)