5.4.2 PumpCfgEntry Table

The cerent15216EdfaPumpCfgEntry table is used to set or get laser pump control mode configuration.
The associated table command displays a settings summary or allows you to set pumps. See
for variable definitions. The factory default pump control mode for the ONS 15216 EDFA2 is Constant
Gain Temperature Compensated. Cisco recommends that users contact the Cisco TAC prior to changing
this mode of operation.
Table 5-7
Variable
cerent15216EdfaPumpCfgP
umpNum
cerent15216EdfaPumpCfgC
ontrolMode
cerent15216EdfaPumpCfgC
onstPumpCurrent
cerent15216EdfaPumpCfgC
onstPumpPower
cerent15216EdfaPumpCfgC
onstOutPower
5.4.2.1 Changing the Pump Control Mode
For Constant Gain Temperature Compensated mode, the system automatically sets the second pump to
this mode when either pump is set.
Constant Output Power mode is only valid for pump 2. If pump 2 is set to Constant Output Power Mode,
pump 1 is automatically set to Constant Pump Power mode with a value of 75 mW.
For Constant Pump Current or Constant Pump Power mode, the user should set both pump modes to be
the same.
Warning
The pump control modes Constant Pump Current, Constant Pump Power, and Constant Output Power
are to be used with very high precautions. They are service affecting and can reduce the life cycle of
the lasers if used in extreme conditions. The factory default setting and recommended mode of
operation is Constant Gain Temperature Compensated mode. Cisco recommends that users contact
the Cisco TAC before changing from this mode of operation.
Cisco ONS 15216 EDFA2 Operations Guide
5-14
F I N A L D R A F T - C I S C O C O N F I D E N T I A L
cerent15216EdfaPumpCfgEntry Variable Descriptions
Maximum
Syntax
Access
cerent15216Edfa
Not
PumpNumber
Accessible
cerent15216Edfa
Read-write
ControlMode
Integer (0 to 300) Read-write
Integer (0 to 100) Read-write
Integer (0 to 650) Read-write
Chapter 5
SNMP MIB Installation and Configuration
Description
Laser pump number (1 or 2).
Laser pump control mode. When the
mode is set directly to constCurrent,
constPower, or constOutputPower, the
current value of ConstPumpCurrent,
ConstPumpPower, or ConstOutPower
is used as the constant parameter for
the new mode.
Constant pump current (mA).
The current that is used when the
pump control mode is changed to
constCurrent.
Constant pump power (mW). The
power that is used when the control
mode is changed to constPumpPower.
Constant output power (*10 mW). The
power that is used when the control
mode is changed to
constOutputPower.