Air Filter Indicator - Grizzly G0533 Owner's Manual

3hp dry spray booth
Hide thumbs Also See for G0533:
Table of Contents

Advertisement

Air Filter Indicator

Components and Hardware Needed:
Air Filter Indicator (Manometer) ..........................1
Tubing Connector Fitting ....................................1
Tubing .................................................................2
Plastic Clip ..........................................................1
Tap Screw M4 x 12 .............................................1
Tap Screws M4 x 45 ...........................................2
To install the air filter indicator:
1.
Mount the manometer to the side of the spray
booth by threading the M4 x 45 tap screws
into the pre-drilled holes (Figure 15).
Figure 15. Mounting manometer to spray booth.
2.
Adjust the manometer so the built-in level
reads level (Figure 15).
3.
Install a tubing connector fitting in the larger
pre-drilled hole on the side of the booth near
the manometer as shown in Figure 16.
G0533 3HP Dry Spray Booth
Qty
Figure 16. Tubing installed onto spray booth
4.
Run tubing from the low pressure side (-) of
the manometer to the tubing connector fitting
as shown in Figure 16.
5.
Install tubing into the high pressure side (+) of
the manometer and secure it with the plastic
clip and an M4 x 12 tap screw as shown in
Figure 17.
Built-in
Plastic
Level
Clip
chamber.
Figure 17. Tubing secured with clip.
Tubing
Connector
Fitting