3. Remove the AUTOFEED assembly, guide tube, inner
drum and main drum as described in Steps 3-9 in
Installing Extra Drum (Additional Cable) section.
4. Remove the bolt anchoring the pigtail. It is located on
the back of the drum (Figure 23) .
Figure 23 – Removing Pigtail Anchoring Bolt
5. Remove the pigtail from drum and insert new pigtail
into the drum.
6. Align hole in pigtail fastener with the hole in the back
of the drum. Insert bolt, washers and nut and tighten
securely. Push the remainder of the pigtail into drum
(Figure 24) .
Figure 24 – Anchoring of Pigtail in Drum
7. Install drum onto the mounting boss and insert rear
support bolt. Securely tighten bolt.
8. Grasp the end of pigtail and reverse Steps 3-7 in
Installing Extra Drum (Additional Cable) section.
Tighten all fasteners, especially the set screw on the
knob on the center shaft.
1.800.561.8187
www.
.com
K-7500 Drain Cleaning machine

Proper Tool Selection

A good rule of thumb is to make the first pass with either
a spear cutter or blade cutter that is 2" smaller than the
drain size. For additional passes, larger tools may be
used. However, tools should always be at least 1" smaller
than the drain size.
The style of the tool is determined by the nature of the job
and is left to the discretion of the operator.
Flexible leaders should be used to negotiate bends and
traps in lines.

Accessories

WARNING
Only the following RIDGID products have
been designed to function with the K-7500 Drain Cleaning
Machine. Other accessories suitable for use with other
tools may become hazardous when used on the K-7500.
To prevent serious injury, use only the accessories listed
below.
Catalog No.
Description
60042
Drum Assembly w/
61107
Drum Assembly w/
60047
Drum Only
60032

AUTOFEED Assembly

" Repair Splicer
31487
5
/
8
" Male Coupling
92805
5
/
8
" Female Coupling
92810
5
/
8
" Repair Splicer
31492
3
/
4
" Male Coupling
92880
3
/
4
" Female Coupling
92885
3
/
4
41937
Pair of Work Gloves
59360
Tool Box
49032
Front Guide Hose Assembly
59982
Cable Rust Inhibitor, 1 Qt.
59987
Cable Rust Inhibitor, 1 Gal.

Maintenance Instructions

WARNING
Make sure machine is unplugged from power source
before performing maintenance or making any ad-
justment.
AUTOFEED Assembly
Proper cleaning and lubrication of the AUTOFEED is ad-
vised for long, trouble-free operation. After each use, hose
out AUTOFEED with water and grease bearings.