01 Activated By:
Zone List
"A"
01 Zn List
"B"
01 Enter Zn type
Perimeter
www.PDF-Zoo.com
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Zone List
01-08 = zone list
1
[∗] to continue
Zone Type
see list at right
03
firealarmresources.com
Section 7: Output Device Programming (
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Do not use pager zone lists 09-10 in output definitions.
Press [ ✱ ] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [ ✱ ] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night 12 = Monitor Zone
01 = Ent/Exit #1
06 = 24 Hr Silent
02 = Ent/Exit #2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower 09 = Fire
10 = Interior w/Delay
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming
31 = End of Exit Time
32 = Start of Entry Time 41 = AC Power Failure
33 = Any Burglary Alarm 42 = System Battery Low
*Fire Zone Reset and Bell Fail Triggers cannot be used.
***Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Press [ ✱ ] to continue and skip to the "Output Action" prompt.
79 and
80 Menu Mode)
Press 1 to delete this
output definition.
0 = restore; 1 = alarm;
1
2 = fault; 3= trouble
14 = Carbon Monoxide
23 = No Alarm Response
24 = Silent Burglary
81 = AAV Monitor Zone
90-91 = Configurable
36 = At Alarm Timeout***
52 = Kissoff
38 = Chime
54 = Fire Zone Reset*
39 = Any Fire Alarm
58 = Duress
40 = Bypassing
60 = AAV
66 = Function Key†
67 = Bell Fail*
43 = Comm. Failure
68 = Telco line cut
7–3