Honeywell ADEMCO LYNX XL Series Installation And Setup Manual page 41

Table of Contents

Advertisement

PROMPT
Entd
A022-4063
Rcvd
A022-4064
Zn ZT RC In
10 03
10 RF: 1s
Note that an "s"
indicates that a
transmitter's serial
number has been
enrolled.
Wireless Key Programming Templates
This procedure programs the wireless keys, but a key is not active until it is assigned to a user
number (see System Operation section, assigning attributes command).
If the D key was previously pressed (from *58 Menu mode) to enter and duplicate 5804 and/or
5804BD wireless keys, the following screens appear.
PROMPT
TEMPLATE ?
1–6
L
01
02
03 04
T
23
22
21 23
ENTER START ZONE
00 = QUIT
36
INPUT S/N
AXXX-XXXX
www.PDF-Zoo.com
VALID ENTRIES
If Serial or Loop
Numbers do not match
after activating the
transmitter
[∗] to continue
Summary Screen
L
[∗] to continue
VALID ENTRIES
Template Number
1–3 = 5804 templates
1
4–6 = 5804BD templates
[∗] to continue
Template Display
[∗] to continue
Start Zone Number
[∗] to continue
Serial Number
L
[∗] to continue
firealarmresources.com
Section 6: Zone Programming (
EXPLANATION
If the serial/loop number combination transmitted does not match the
serial and loop number entered, a display similar to the one below
will appear. If the loop number does not match, it will also be
displayed. If so, activate the transmitter's loop input or button one
or more times.
If a match is still not obtained (i.e., summary display does not
appear), press the [#] key twice and enter the correct loop input or, if
correct, press [#] again and then enter the correct serial number.
If the serial number transmitted matches the serial number entered,
the keypad will beep 3 times and a summary display will appear,
showing the programmed information for that zone.
Press [✱] to begin programming the next zone. See first "Summary
Screen" prompt paragraph on previous page.
EXPLANATION
1. Enter Template number 1–6 (from next page).
See the defaults provided for each template in the chart that
follows these procedures.
2. Select from templates. Press [✱] to display template (1 shown
selected). NOTE: If necessary, press [#] to back up and re-enter
template number.
3. Press [#] if you want to return to zone attributes screen.
4. When [✱] is pressed, the selected template will be displayed.
Top line of display represents loop numbers, bottom line
represents zone type assigned for each loop.
5. Press [✱] to accept template.
8. The system will search for the highest available consecutive 4-
zone group (the four zones in the case of the 5804 and 5804BD),
and display the lowest zone number of the group.
If you want to start at a different zone, enter the zone desired, and
press [✱]. If that zone number is displayed, the system has the
required number of consecutive zones available, beginning with
the zone you entered. If not, the system will again display a
suggested zone that can be used.
If the required number of consecutive zones is not available at all,
the system will display "00".
9. Press [✱] to accept.
10. Manually enter the serial number printed on the label for the
wireless key or press and release the button to transmit its serial
number.
11. Press [✱] to accept the serial number. The system will check for
duplicate.
12. If necessary, press the [#] key to back up without saving, and re-
enter the serial number.
Use the [A] key to move forward within the screen, and the [B] key to
move backward.
56 and
58 Menu Modes)
5–5