FIELD
TITLE and DATA ENTRIES
Low Bat Report Code
*63
0 = no report
1-F = see description above *59
Test Report Code
*64
0 = no report
1-F = see description above *59
† NOTE: Make sure the Real-Time Clock
is set to the proper time before entering
the test report schedule command to
ensure that test reports are sent when
expected. (see Setting the Real-Time
Clock section)
Open Report Code
*65
0 = no report
1-F = see description above *59
Arm Away/Stay Report Code
*66
0 = no report
1-F = see description above *59
RF Trans. Low Batt. Report Code
*67
0 = no report
1-F = see description above *59
Cancel Report Code
*68
0 = no report
1-F = see description above *59
Alarm Restore Report Code
*70
0 = no report
1-F = see description above *59
Trouble Restore Report Code
*71
0 = no report
1-F = see description above *59
FIELD
TITLE and DATA ENTRIES
Bypass Restore Report Code
*72
0 = no report
1-F = see description above *59
AC Restore Report Code
*73
0 = no report
1-F = see description above *59
Low Bat Restore Report Code
*74
0 = no report
1-F = see description above *59
RF Xmtr Low Batt. Restore Code
*75
0 = no report
1-F = see description above *59
Test Restore Report Code
*76
0 = no report
1-F = see description above *59
www.PDF-Zoo.com
EXPLANATION
Sent when a low-battery condition exists in the system's battery.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent periodically to test that the communicator and phone lines are
operational.
(event 11) or by the following key commands:
installer code + [#] + 0 + 0 = test report sent every 24 hrs
installer code + [#] + 0 + 1 = test report sent once per week
installer code + [#] + 0 + 2 = test report sent every 28 days
Each of these modes sets schedule 8 to the stated repeat option;
first test report sent 12 hours after command
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
This is sent upon disarming of the system.
UL: Required for UL commercial burglar alarm installations.
This option allows for independent programming of Away and Stay
reports.
NOTE: "OPEN" reports are not sent if the associated closing report is
not enabled.
Sent when a wireless transmitter low-battery condition exists.
UL installations: must be enabled if wireless devices are used.
This is sent upon disarming of the system after an alarm condition
was reported.
Sent when an alarm zone is restored to its non-faulted condition.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
This is sent when a trouble in a zone is restored
UL: Required for UL commercial burglar alarm installations.
EXPLANATION
This is sent when a zone that has been bypassed is unbypassed.
UL: Required for UL commercial burglar alarm installations.
Sent when AC power has been restored after an AC power outage.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent when a system low-battery condition is restored to normal.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
Sent when a transmitter's low battery condition is restored (i.e., new
battery installed).
UL installations: must be enabled if wireless devices are used.
Required for UL commercial burglar alarm installations and required
for residential fire alarm installations.
This is sent when the Test mode is exited.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
firealarmresources.com
Section 4: Data Field Programming
Frequency of report is set in Scheduling mode
.
4–5