LXL-1010 Installation and Setup Guide
Output and System Setup (*77 - *93)
FIELD
TITLE and DATA ENTRIES
Daylight Saving Time
*77
Start/End Month
0 = Disabled
1 = Jan
2 = Feb
3 = Mar
Daylight Saving Time
*78
Start/End Weekend
0 = disabled
1 = first
2 = second
3 = third
Output Device Mapping Menu Mode
*79
Output Programming Menu Mode
*80
Zone List Programming Menu Mode
*81
Alpha Descriptor Programming
*82
Menu Mode
Auto-Stay Arm
*84
0 = no
1 =yes
Cross Zone Timer (in seconds)
*85
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
Cancel Verify Keypad Display
*86
0 = no
1 = yes
Misc. Fault Delay Time
*87
0 = 15 secs
1 = 30 secs
2 = 45 secs
3 = 60 secs
4 = 90 secs
5 = 2 min
4–6
www.PDF-Zoo.com
4 = April
# + 10 = Oct
# + 11 = Nov
# + 12 = Dec
4 = fourth
5 = last
6 = next to last
7 = third to last
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
6 = 2-1/2 min #+12 = 8 min
7 = 3 min
#+13 = 10 min
8 = 4 min
#+14 = 12 min
9 = 5 min
#+15 = 15 min
#+10 = 6 min
#+11 = 7 min
firealarmresources.com
EXPLANATION
Enter the start and end month for daylight savings time, if
applicable to the region.
Enter the start and end weekend for daylight savings time, if
applicable to the region.
Use this menu mode to enter powerline carrier devices into the
system. See Output Device Programming section for procedures.
Use this menu mode to define output functions for use with
output powerline carrier devices. See Output Programming
section for procedures.
Use the menu mode to define zone lists. See Zone List
Programming section.
Use this menu mode to assign alpha descriptors.
When this field is enabled, if the system is armed in AWAY
mode at a keypad, it will automatically reverts to armed STAY
mode if a door is not opened and shut within the programmed
exit delay time (if armed MAXIMUM it will revert to INSTANT).
An Opening report followed by an Armed Stay report is sent to
the Central Station. Any RF keyfob that arms the system AWAY
overrides this feature and the system remains armed in the
AWAY mode.
Sets the maximum amount of time in which two cross zones
must be tripped in an armed system to send an alarm message
to the Central Station. If only one cross zone is tripped during
this time, a trouble message (CID code 380) for that zone is sent
to the Central Station.
Assign cross zone pairs in zone list 4.
This option not for use in UL installations.
When enabled (1 = yes), this feature causes a "CANCELED
ALARM" display on the LCD keypad under the following
conditions:
After the kissoff of the cancel message to the Central Station,
indicating a successful transmission.
When an alarm is successfully canceled before the Central
Station received the Alarm message. E.g., if an alarm is
incorrectly triggered and the user presses code + OFF before
the dial delay time has expired, the message will never go out
to the CS.
When the Cancel report is not enabled and the system is
disarmed:
a. before dialer delay expires (alarm report not sent)
message "Canceled Alarm" is displayed.
b. after dialer delay expires message "Canceled Alarm" is not
displayed .
Used with zones assigned to a configurable zone type with fault
delay on (configurable zone type digit "6"), and sets a zone
response time of 15 seconds to 15 min. It can be assigned to
zones with sensors that provide a trouble indication when an oil
tank is low, or similar applications for critical condition
monitoring where a non-alarm response is desired.
UL: May only be used on non-burglar alarm and non-fire alarm
zones when used on a fire and/or UL burglar alarm installation.