Mounting The A700/A700X Battery Charger - Honeywell Vocollect A700 Series Product Manual

Hide thumbs Also See for Vocollect A700 Series:
Table of Contents

Advertisement

Part Number in Diagram
1
2
3
4
5

Mounting the A700/A700x Battery Charger

You will need:
Drill
l
Fasteners
l
Screw driver
l
DIN rail, slotted steel 35 mm X 15 mm, Honeywell Part #CM-1000-20-101
l
or customer-supplied DIN rail meeting the following specifications :
Number
of
Minimum cut lengths
chargers
for rail
on rail
1
550 mm
2
1101 mm
3
1652 mm
1. Install the DIN rail on the wall in the desired location. Ensure that the secure
installation, supporting surface, and mounting hardware will safely support
the weight of a fully loaded charger, at 25 lbs. per linear foot (37.2 kg/m) of
DIN rail. Ensure that the anchor holes are at least 12 inches (30.5 cm.) from
the floor. Verify that the installation meets all local building codes.
A700x Product Guide
Description
power supply
rubber stop for leveling charger against wall
locking arm for securing charger to DIN rail
mounting hook for hanging charger on DIN rail
USB port for charger software upgrades (only on battery charger)
DIN rail specs
Single unit length 550 mm; weight 331.5 g
(11.6933 oz)
Standard
DIN rail
36