Installation Instructions

Configurable Zone Type Programming (*83 Menu Mode)

Start Configurable Zone Type Programming Mode by pressing ∗ 83 while in Data Programming mode.
UL installations: Do not configure zones as fire alarm or UL burglar alarm zones.
E n t e r Z o n e T y p e
( 0 0 = q u i t )
9 0
9 0 Z n A t t r i b u t e s
0
9 0 B y p a s s O p t i o n
0
9 0 R e s p t o S h o r t
A r m e d 0
D A r m d 0
9 0 R e s p t o o p e n
A r m e d 0
D A r m d 0
9 0 V e n t Z o n e
0 = N o , 1 = Y e s
9 0 A l m / T r b l P r o c
0
9 0 T R B L S O U N D
0
9 0 A L A R M S O U N D
0
5-16
Zone Type Number
90-93 = zone type
[∗] to continue
Zone Attributes
0 = none
1 = exit delay only
2 = entry/exit 1
3 = entry/exit 2
4 = follows entry/exit
5 = has verification (resets
power upon event and when
code + OFF to clear condition. If
condition persists, zone
activates)
6 = resettable (upon code +
OFF)
[∗] to continue
Bypass Option
0 = zone type cannot be
bypassed
1 = auto bypassed when armed
in stay mode
[∗] to continue
Response to Shorts
0=none
2=trouble
1=Alarm
3=fault
[∗] to continue
Response to Opens
0 = none
2 = trouble
1 = Alarm
3 = fault
[∗] to continue
Vent Zone?
0=no
1=yes
[∗] to continue
Alarm/Trouble
Processing
0=none
1=Zone type has automatic
restore
2=zone type uses Misc. Fault
Delay Time and automatic
restore
[∗] to continue
Trouble Sounding
0= none
1= one beep every minute
2= normal trouble sound (fast
beeps)
[∗] to continue
Alarm Sounding
0=none
1= keypad sound only
2= steady siren sounding
3= pulsing siren (temporal)
[∗] to continue
Enter the configurable zone type number being programmed.
Enter the desired zone attributes.
Enter the desired bypass option.
Select the type of response when zones assigned to this zone type are
shorted when the system is armed.
NOTES: 1. For double-balanced zones, this entry must be 0.
2. For zone-doubled zones, both zones of the doubled pair
must be assigned the same response to a short.
Select the type of response when zones assigned to this zone type are
opened when the system is armed.
If selected, the system can be armed even if zones assigned to this
zone type are faulted.
NOTE: After arming, faults on these zones will be ignored until the
zone is restored.
Select desired actions for zones assigned to this zone type.
Option 2: Select Miscellaneous Fault Delay in field *87.
Select type of sounding upon trouble conditions on zones assigned to
this zone type.
Select type of sounding upon alarm conditions on zones assigned to
this zone type.