01 Activated By:
Zone List
"A"
01 Zn List
1
"B"
01 Enter Zn type
Perimeter
03
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[∗] to continue
Zone List
01-12 = zone list
[∗] to continue
Zone Type
see list at right
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to "A" prompt)
2 = zone type (go to "B" prompt)
3 = zone number (go to "C" prompt)
If you enter "0," the following prompt appears:
Delete?
0 = NO, 1 = YES
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Zone lists 09-12 can be used in output definitions if not used
for paging or for exit zone definition.
Press [ ∗ ] to continue.
Enter the zone list event that will activate this output.
Enter Event
Alarm
1
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [ ∗ ] to continue and skip to the "Output Action" prompt.
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night 14 = Gas
01 = Ent/Exit #1
06 = 24 Hr Silent
02 = Ent/Exit #2
07 = 24 Hr Audible
03 = Perimeter
08 = 24 Hr Aux
04 = Interior Follower 09 = Fire
10 = Interior w/Delay
12 = Monitor Zone
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Siren Timeout***
21 = Arming–Away
38 = Chime
22 = Disarming
39 = Any Fire Alarm
31 = End of Exit Time
40 = Bypassing
32 = Start of Entry Time 41 = **AC Mains Failure
33 = Any Burglary Alarm 42 = **System Battery Low 68 = Telecom Line Cut
43 = Comm. Failure
52 = Kissoff
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function "07").
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
Any partition
0
Press [ ∗ ] to continue and skip to the "Output Action" prompt.
Press 1 to delete this
output definition.
0 = restore; 1 = alarm;
2 = fault; 3= trouble
16 = Fire w/verification
23 = No Alarm Response
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
82 = Blockschloss
90-93 = Configurable
54 = Fire Zone Reset
58 = Duress
60 = AAV
66 = Function Key†
67 = Siren Fail
78 = Keyswitch Red LED
79 = Keyswitch Green LED
80 = Tamper Fault
0 = any partition; 1 = partition 1;
2 = partition 2; 3 = partition 3
5-11