Download Print this page

RIDGID 1000RSDSSmart Installation Manual page 7

Smart submersible sump pump

Advertisement

INSTALLATION MANUAL
LED LIGHT DISPLAY
Color
Green
Yellow
Red
DIGITAL CONTROLLER BUTTON
Function
Mute Alarm
System Test
Reboot
Reset WiFi
Connection and
Reboot
Reset to Factory
Settings and
Reboot
A Button Hold Legend can be found on the back of the controller for your convenience.
7
(CHECK YOUR APP FOR SPECIFIC REAL TIME PUMP INFORMATION)
Symptom/Possible Cause(s)
1. Good
1. A clogged pump inlet
2. Electrical voltage or
polarity issue detected
3. Water level in your pit is
not dropping
4. Your motor is showing
signs of aging
1. There is a critical issue
with your pump
Action to Take
Short press (at least 1 second)
Hold for 5 seconds (pump health LED will flash blue) and release
Hold for 10 seconds (pump health LED will flash green) and release
Hold for 15 seconds (pump health LED will flash yellow), release and short
press (at least 1 second) again to confirm
Hold for 20 seconds (pump health LED will flash red), release and short press
(at least 1 second) again to confirm
Suggested Remedies
1. Your pump is good, there is nothing needed
1. Open your sump pit and inspect the pump.
Make sure the inlet screen is free of debris and
there is nothing blocking the fow of water into
the pump.
2. Contact an electrician and have them check the
voltage and wiring of the outlet.
3. Check your pump to be sure it is properly
connected. Then check your discharge pipe for
obstructions or leaks that allow water back into
the pit.
4. Consider replacing your pump soon to stay
protected.
1. Replace your pump immediately.

Advertisement

loading