Note: Door sense is considered open when sensor switch is open
EACH DOOR STRIKE REQUIRES A
14507020‐001 DIODE SUPPRESSION
1 1
NETWORK. DOOR STRIKE MAY DRAW A
MAXIMUM CURRENT OF 2A; REGULATED 12/ 24
VDC. DOOR STRIKE MUST BE UL LISTED.
DOOR CONTACTS MUST BE UL LISTED.
2 2
MAXIMUM WIRE LENGTH 500 FT (152M).
WIRE TYPE 18 AWG (0.8 SQ MM), 50 OHM 60
mA MAXIMUM.
SAI-n
SAI-n
SAI-n GND
SAI-n GND
Fig.26. Supervisory Analog Inputs
Honeywell IdentIPoint Intelligent Smartcard Readers
1KΩ
1KΩ
3 3
AREA OR NOT READILY ACCESSIBLE OUTSIDE THE
PROTECTED AREA.
4 4
ORDINANCES, AND REGULATIONS
5 5
DEVICES.
NOTE: FOR COMMUNICATION CIRCUITS AND
OTHER APPLICABLE WIRING CIRCUITS WHERE
WIRING ENTERS AND EXITS THE BUILDING,
REFER TO LIGHTNING PROTECTOR TABLE FOR
APPROPRIATE LIGHTNING PROTECTOR USAGE.
27
Sensor
Sensor
Switch
Switch
EXIT SWITCH: WIRING MUST BE
COMPLETED WITHIN THE PROTECTED
ALL WIRING MUST CONFORM TO
APPLICABLE LOCAL CODES,
DO NOT ROUTE COMMUNICATION
WIRES WITH POWER OR LOCKING
95-7771