PROBLEM
POSSIBLE CAUSES
•
Does not operate,
A disconnection between the water
and 'EO' displays on
sensor internal wiring.
the display screen
•
Does not operate,
The connection on the water
and 'E1' displays on
sensor is loose.
the display screen
•
Incorrect relative
The room is larger than the effective
humidity level is
range of the humidifier.
displayed.
•
Moisture has built up inside of the
humidity sensor.
•
The nozzle is facing the direction of
the humidity sensor.
•
Humidity sensor is broken
or defective.
•
Control panel does
Hands are too wet when operating
not work.
control panel.
•
Humidifier has malfunctioned.
•
White dust
Water being used has a high
appears around the
mineral content.
humidifier.
•
Humidifier was not properly cleaned
after last use.
•
Mist is coming out
The water tank isn't positioned
from the base.
correctly in the housing.
•
Mist fog coming out
The nozzle is not correctly fitted.
from around nozzle
or water is leaking
from the lid.
•
The warm mist
The humidifier is still warming up.
function does not
•
produce warm mist.
The mist is too fine to
feel the warmth.
•
The room temperature is too
cold and the mist may cool down
too quickly.
•
Remote control is
Remote control is out of range of
not working.
the humidifier.
•
The plastic tab is still in.
•
Battery needs to be changed.
26
WHAT TO DO
•
Switch the unit off and contact the
Breville Customer Service Centre.
•
Switch the unit off and contact the
Breville Customer Service Centre.
•
Move the humidifier to a room which is
within the recommended room size.
•
Turn off the humidifier and allow the
humidity sensor to completely air dry
before resuming use.
•
Turn the nozzle so it is facing away from
the humidity sensor.
•
Switch the unit off and contact the
Breville Customer Service Centre.
•
Keep hands dry while operating the
control panel.
•
Switch the unit off and contact the
Breville Customer Service Centre.
•
Use distilled water with the humidifier.
If distilled water is not available, use
purified or filtered water. Clean the
water tank at least once a week as per
instructions in this book.
•
Clean the humidifier as per instructions
in this book.
•
Check the positioning of tank.
•
Reposition the cover and check if the
nozzle is plugged in correctly.
•
Wait a few minutes before
checking again.
•
Increase the mist level.
•
Increase the mist level and heat the room.
•
Use the remote control within 5m of
the humidifier.
•
Remove the plastic tab from the battery
compartment.
•
Replace the battery.