OPERATION INSTRUCTIONS
NOTE: Other cylinders may be acceptable for use with this appliance If they are compatible with the app-
-liance nesting hole and retention means. Refer to Page11 of the Assembly Instructions for corr-
e ct cylinder to cylinder holder connection.
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE AND/OR INJURY.
CONNECTING THE LP TANK
1. The knob on the LP tank must be closed. Make sure that the knob is turned
full stop. The cylinder supply system must be arranged for vapor withdrawal.
2. Check that the control knob on the control unit is turned off.
3. Remove the protective cap from the LP tank valve and coupling nut.
4. Hold the regulator in one hand and insert the nipple into the valve
outlet. Be sure the nipple is centered in the valve outlet. The coupling
nut connects to the large outside threads on the valve outlet. Use
care – do not cross thread the connection.
5. Hand-tighten the coupling nut
stop. Firmly tighten by hand only. Do not use tools.
To Disconnect: Fully close the tank valve by turning
Turn the coupling nut
In the connection process, make sure:
• the regulator inlet connector mates with the cylinder valve o
WARNING
clockwise until it comes to a full
counterclockwise until the regulator assembly detaches.
WARNING
14
clockwise.
clockwise to a