F111 (SERIES 3) IN CEILING MEDIA AIR CLEANER
TOP OF METAL CABINET
THREADED
ROD
JAM
NUT
CHAIN
EYEBOLT
JAM NUT
3/8 IN. X 16T
OR USING OPTIONAL "Z" BRACKETS
TOP OF METAL CABINET
NOTE:
FASTEN SECURELY TO STRUCTURAL
SUPPORT SYSTEM, I.E. BAR JOIST,
CONCRETE SLAB OR TIMBER FRAMING.
BOTTOM FLANGE AGAINST
UNDERSIDE OF TEES
Fig. 4. Fasten cabinet to a structural support.
IMPORTANT
Do not touch the pleated filter media. Handle only
the filter frame to prevent damage to the filter
media.
10. Remove CPZ™ sorbent modules (select models) from
their packaging and install one module into each
cavity.
11. Be sure both catches are turned down and filter rests
firmly on catches.
12. Install the prefilter in the air cleaner lid. Position the
prefilter so that the Air Flow Direction Arrow is facing
upward when the lid is closed.
Remote 3 Speed Wall Switch
The 190097C Remote Wall Switch Assembly allows control
of the F111 model air cleaners from a a location separate
from the air cleaner. The assembly includes a remote
switch with an outlet box cover, outlet box, extension ring,
and a wire harness. Wiring to connect the remote switch
and air cleaner must be furnished separately.
68-0198—05
HEX BOLT
LOCK
WASHER
"Z" BRACKET (4)
CEILING
TEE
BOTTOM VIEW OF
UNIT WITHOUT
LID ASSEMBLY
M10892
CAUTION
• This installation to be performed only by a
qualified installer.
• All wiring to comply with local electrical codes.
• Disconnect power to air cleaner at fuse or breaker
before beginning work. Failure to do so can result
in shock hazard endangering equipment and
personal safety of installer.
• Only one air cleaner can be connected to a remote
switch
A100001
Fig. 5. Wiring F111 Series 3 Air Cleaner
1. Disconnect power to air cleaner.
2. Mount 4" x 4" outlet box at desired remote location.
3. Attach 3/4" extension ring to outlet box.
4. Run five conductor, color-coded, 18-gauge wires
from the remote switch location to the air cleaner.
At REMOTE SWITCH:
5. Use three wire nuts to connect three color-coded,
wires on the remote switch to three color-coded wires
running to the air cleaner. (Red, Blue, Violet)
6. Use one wire nut to connect white color-coded, wire
running to the air cleaner to the Neutral wire from the
power source/electrical panel. (White)
A100001
Fig. 6. Wiring 3-Speed Remote Switch