Honeywell F116 Series Product Data

Honeywell F116 Series Product Data

2 self-contained ductable commercial air cleaner
Hide thumbs Also See for F116 Series:

Advertisement

Quick Links

F116 Series 2 Self-Contained
Ductable Commercial Air Cleaner
APPLICATION
The F116 Series 2 Self-Contained Ductable Commercial
Air Cleaner is a media air cleaner that uses a three-speed
direct drive forward curve blower/motor with a variety of
filter combinations to remove airborne contaminants. The
air cleaner is designed to provide its own air circulation. In
addition it can accommodate ducting which can be
attached to the intake and/or the outlet of the cabinet as
the application requires.
If equipped with HEPA filter the air cleaner is suitable for
the collection of smoke, bacteria, gases, odors and volatile
organic compounds (VOCs), fine saw dust, paper dust,
brazing, normal atmospheric dusts such as pollens,
allergens, dust mites and soot, and virtually any other
respirable airborne contaminant. When equipped with
CPZ™ modules, gases and odors are adsorbed from the air
passing through the unit.
FEATURES
• Three levels of filtration:
99.97% High Efficiency Particulate Air (HEPA)
Hospital grade filter 95% efficient at 0.3 micron
(MERV 16)
95% ASHRAE (MERV 12)
• Circulates up to 2600 cfm.
• Designed to overcome the increase in air flow
resistance normally caused by filter loading.
• Negative and positive pressure rooms can be created
with air cleaner.
• CPZ™ module removes up to 95% of the space odors
for up to 24 months.
• 3-Speed remote wall switch.
• 120 Vac, 60 Hz models available.
PRODUCT DATA
68-0200-07

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F116 Series

  • Page 1 APPLICATION • 3-Speed remote wall switch. • 120 Vac, 60 Hz models available. The F116 Series 2 Self-Contained Ductable Commercial Air Cleaner is a media air cleaner that uses a three-speed direct drive forward curve blower/motor with a variety of filter combinations to remove airborne contaminants.
  • Page 2: Specifications

    1475 (2500) (MERV 12) All Models come with 30% ASHRAE Prefilter in Bay 1. Table 2. F116 Series 2 Filter Configuration, Internal Static Pressure, and Hanging Weight with Filters. Starting Internal Static Pressure Hanging Weight Filters ( 2 stage and 3 stage)
  • Page 3 F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER Table 3. F116 Series 2 Filter Description. Dimensions in Filter inches (mm) Efficiency Description Sorbent Module Options: • Charcoal only Disposable filter with at least • Permanganate only 12 x 12 x 22 85% first pass at 1600 cfm twenty pounds of CPZ.
  • Page 4 F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FRONT VIEW 7/8 (22) FLANGE 13-1/2 (343) 16 TYP 24-1/4 (406) (616) (1219) (254) 5 TYP 22-1/4 (127) (565) 12-1/8 (308) (178) 3/8 THREADED INSERT HOLE FOR HANGING INSTALLATION (660) (660) SORBENT MODULES HEPA, D.O.P.
  • Page 5 F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER FRONT VIEW 7/8 (22) FLANGE 13-1/2 (343) 16 TYP (406) 24-1/4 (616) (1626) 5 TYP (254) (127) (432) 12-1/8 (308) 21-1/4 (178) (540) 3/8 THREADED INSERT HOLE FOR A HANGING INSTALLATION (660)
  • Page 6: Planning The Installation

    Consult with a mechanical engineer or contractor experienced in duct design and pressure calculations for WARNING assistance in ducting your F116 Series 2 air cleaner. TO REDUCE THE RISK OF FIRE,ELECTRICAL SHOCK, OR INJURY TO PERSONS,OBSERVE THE Choose Location...
  • Page 7 F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER S m ok in g S ec tio n N on - S m ok in g M7783 Fig. 5. Positioning air cleaners at the far end of the restaurant smoking section to draw the smoke away from the nonsmoking section.
  • Page 8 F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER AIR CLEANER AIR CLEANER STATIONARY FLEXIBLE M10799 Fig. 7. Positioning air cleaner for suspended side draft applications. DO NOT INSTALL WHERE THERE IS HEAVY OIL SMOKE, COOKING, HEAVY WELDING OR HEAVY CUTTING.
  • Page 9: Installation

    1. Read these instructions carefully. Failure to follow Can cause personal injury or equipment damage. them could damage the product or cause a hazard- Do not install or use the F116 Series 2 air cleaner ous condition. where there is any danger of gas, vapor or dust 2.
  • Page 10 AIR CLEANER installation or initial power on. Mount Air Cleaner Cabinet The F116 Series 2 air cleaner must be attached to a structure capable of supporting the weight of the unit with M7793A filters, ducting and plenums when used. Roof trusses, bar joists and floor joists are examples of suitable structures.
  • Page 11: Electrical Hookup

    A100002 coded wire from the power supply. 10. Fold wires into box and mount remote switch on out- Fig. 16. Typical F116 Series 2 only 120V, 60 Hz wiring let box. Leave switch in OFF position. diagram. 11. On the air cleaner remove two screws on wiring com-...
  • Page 12: Operation

    OPERATION CAUTION Electrical Hazard. Because the F116 Series 2 air cleaner provides its own Can cause personal injury or equipment damage. circulation, it can be mounted independently or in a duct Turn off power before installing or servicing the air system.
  • Page 13: Troubleshooting

    5. Replace the primary media filter(s) when there is a noticeable loss of air volume from the air cleaner (approximately every 12 - 18 months) Table 4. Troubleshooting the F116 Series 2 Air Cleaner Model* Electrical Ratings • Check wiring for loose connections - Tighten if necessary.
  • Page 14: Parts List

    F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER PARTS LIST Refer to Fig. 18 and Table 5 for replacement part information. Table 5. Replacement Parts. Fig. Reference No. Description Pack Qty Order Number Prefilter 1 box of 6 32000200-001 99.97% HEPA media filter 32000198-001 95% D.O.P hospital grade filter (MERV 16)
  • Page 15 (SORBENT MODULES) (PREFILTER) (HEPA, D.O.P. OR ASHRAE FILTERS) 1 TWO STAGE MODELS WILL HAVE ONLY ONE PRIMARY FILTER AREA. M10812B Fig. 18. Exploded view of F116 Series Air Cleaner components. 68-0200—07...
  • Page 16 Honeywell Building Technologies In the U.S.: Honeywell 715 Peachtree Street NE ® U.S. Registered Trademark Atlanta, GA 30308 ©2020 Honeywell International Inc. 68-0200—07 M.S. Rev. 08-20 customer.honeywell.com Printed in United States...

This manual is also suitable for:

F116a1021-3sF116c1112-3sF116c1173-3s

Table of Contents