Download Print this page

Honeywell F111 Series Product Data page 2

In ceiling media air cleaner
Hide thumbs Also See for F111 Series:

Advertisement

F111 (SERIES 3) IN CEILING MEDIA AIR CLEANER
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. There-
fore, this unit may not exactly match the listed
specifications. Also, this product is tested and cali-
brated under closely controlled conditions, and
some minor differences in performance can be
expected if those conditions are changed.
Model
Input Power
F111A1020B-3S 120 Vac, 60 Hz, 7.5A 95% at 0.3 micron (MERV 16)
F111A1020W-3S 120 Vac, 60 Hz, 7.5A 95% at 0.3 micron (MERV 16)
F111A1063B-3S 120 Vac, 60 Hz, 7.2A
F111A1063W-3S 120 Vac, 60 Hz, 7.2A
F111A1253B-3S 120 Vac, 60 Hz, 8.5A
F111A1253W-3S 120 Vac, 60 Hz, 8.5A
F111C1003B-3S 120 Vac, 60 Hz, 7.0A
F111C1003W-3S 120 Vac, 60 Hz, 7.0A
F111C1012B-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron (MERV 16)
F111C1012W-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron (MERV 16)
F111C1073B-3S 120 Vac, 60 Hz, 7.5A
F111C1073W-3S 120 Vac, 60 Hz, 7.5A
Table 2. F111 Air Volume Specifications for 3 Speed Models (Series 3).
Model
Input Power
F111A1020B-3S 120 Vac, 60 Hz, 7.5A 95% at 0.3 micron (MERV 16)
F111A1020W-3S 120 Vac, 60 Hz, 7.5A 95% at 0.3 micron (MERV 16)
F111A1063B-3S 120 Vac, 60 Hz, 7.2A
F111A1063W-3S 120 Vac, 60 Hz, 7.2A
F111A1253B-3S 120 Vac, 60 Hz, 8.5A
F111A1253W-3S 120 Vac, 60 Hz, 8.5A
F111C1003B-3S 120 Vac, 60 Hz, 7.0A
F111C1003W-3S 120 Vac, 60 Hz, 7.0A
F111C1012B-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron (MERV 16)
F111C1012W-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron (MERV 16)
F111C1073B-3S 120 Vac, 60 Hz, 7.5A
F111C1073W-3S 120 Vac, 60 Hz, 7.5A
68-0198—05
Table 1. F111 (Series 3) Description.
Efficiency
V.O.C./Odor (Most
Gases/ Odors First
Filter Rating
Pass Average)
99.97% HEPA
99.97% HEPA
95% ASHRAE (MERV 12)
95% ASHRAE (MERV 12)
99.97% HEPA
99.97% HEPA
95% ASHRAE (MERV 12)
95% ASHRAE (MERV 12)
Gas, V.O.C. and Odor
Filter Rating
Control Modules (2) High in cfm (m
99.97% HEPA
99.97% HEPA
95% ASHRAE (MERV 12)
95% ASHRAE (MERV 12)
99.97% HEPA
CPZ™ modules
99.97% HEPA
CPZ™ modules
CPZ™ modules
CPZ™ modules
95% ASHRAE (MERV 12)
CPZ™ modules
95% ASHRAE (MERV 12)
CPZ™ modules
2
Models: Refer to Table 1 for model descriptions.
Grill Color: White (standard) or Black.
Blower/Motor: Three speed ('-3S' to the end of the model
number) direct drive forward curve.
Dimensions: See Fig. 1 for dimensions.
Gas, V.O.C. and Odor
Control Modules (2)
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
85%
CPZ™ modules
85%
CPZ™ modules
85%
CPZ™ modules
85%
CPZ™ modules
85%
CPZ™ modules
85%
CPZ™ modules
n/a
1050 (1780)
n/a
1050 (1780)
n/a
950 (1610)
n/a
950 (1610)
n/a
1250 (2120)
n/a
1250 (2120)
825 (1400)
825 (1400)
1125 (1910)
1125 (1910)
1150 (1950)
1150 (1950)
Air Volume in cfm,
3
High Speed (m
/hr) Grill Color
1050 (1780)
Black
1050 (1780)
White
950 (1610)
Black
950 (1610)
White
1250 (2120)
Black
1250 (2120)
White
825 (1400)
Black
825 (1400)
White
1125 (1910)
Black
1125 (1910)
White
1150 (1950)
Black
1150 (1950)
White
Medium in cfm
Low in cfm
3
3
/hr)
(m
/hr)
(m
800 (1360)
450 (760)
800 (1360)
450 (760)
775 (1310)
450 (760)
775 (1310)
450 (760)
800 (1360)
450 (760)
800 (1360)
450 (760)
700 (1190)
450 (760)
700 (1190)
450 (760)
825 (1400)
450 (760)
825 (1400)
450 (760)
800 (1360)
450 (760)
800 (1360)
450 (760)
3
/hr)

Advertisement