F111 (SERIES 3) IN CEILING MEDIA AIR CLEANER
WARNING
TO REDUCE THE RISK OF FIRE,ELECTRICAL
SHOCK, OR INJURY TO PERSONS,OBSERVE THE
FOLLOWING:
1. Use This Unit Only In The Manner Intended By The
Manufacturer. If You have Questions, Contact The
Manufacturer.
2. Before Servicing Or Cleaning Unit, Switch Power Off
At Service Panel And Lock Service Panel To Prevent
Power From Being Switched on Accidentally. When
The Service Disconnecting Means Cannot Be Locked,
Securely Fasten a Prominent Warning Device, Such
As A Tag, To The Service Panel.
3. Installation Work And Electrical Wiring Must Be Done
By Qualified Person(s) In Accordance With All Appli-
cable Codes And Standard, Including Fire Rated Con-
structions.
4. When Cutting Or Drilling Into The Wall Or Ceiling, Do
Not Damage Electrical Wiring And Other Hidden Util-
ities.
5. If This Unit Is To Be Installed Over A Tub Or Shower, It
Must Be Marked As appropriate For The Application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) - protected branch circuit.
6. Never Place A Switch Where It Can Be Reached From
A Tub Or Shower.
Choose Location
Choosing the correct location for the air cleaner affects the
overall performance of the unit. The bidirectional airflow
pattern must flow into the longest reaches of the zone
being cleaned. See Fig. 2.
NOTE: The F111 Has Not Been Investigated For Use In Fire
Resistance Rated Construction.
The air cleaner is designed to be suspended centrally in a
space and mounted into or on a ceiling. The cleaning
footprint of the air cleaner is rectangular with air patterns
that move clean air to the corners of the area while drawing
contaminated air up from the center of the area. See Fig. 2.
When multiple air cleaners are installed, the allotted areas
to be cleaned should be equal. The air throw in one
direction is approximately 55 ft (17m). Air velocity at 90 ft
per minute (27m per minute) is considered end of throw
68-0198—05
CLEANING FOOTPRINT
F111
(SERIES
11000)
2
CORRECT
Fig. 2. Correct Positioning of the air cleaner for
optimum cleaning.
IMPORTANT
Never hang the air cleaner higher than 16 ft (5m)
above the floor.
INSTALLATION
WARNING
Explosion Hazard Possible.
Can cause personal injury or equipment damage.
Do not install or use the F111 (Series 3) air cleaner
where there is any danger of gas, vapor or dust
explosion.
IMPORTANT
This air cleaner has not been investigated for use in
the ceilings of fire-resistant assemblies.
CAUTION
Electrical Hazard.
Can cause personal injury or equipment damage.
Turn off power before installing or servicing the air
cleaner.
IMPORTANT
Stand on a stable platform when working with the
air cleaner.
When Installing this Product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazard-
ous condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service tech-
nician.
4. After installation is complete, check out product
operation as provided in these instructions.