Honeywell F111 Series 1 Product Data

Honeywell F111 Series 1 Product Data

In ceiling media air cleaner
Hide thumbs Also See for F111 Series 1:

Advertisement

APPLICATION

The F111 (Series 1,2) Ceiling Media Air Cleaner is a media air
cleaner that uses a single-speed direct drive forward curve
blower motor with particle filter. When equipped with CPZ™
modules (2), gases and odors are absorbed from the air
passing through the unit. The air cleaner removes airborne
particles such as dust, soot, mold spores, pollen and some
cooking smoke from the air circulated through the filter.
The Honeywell Trademark is used under license from Honeywell Intellectual
Properties, inc. by Air-Pure Systems.
Honeywell International Inc. makes no representations or warranties with
respect to this product
In Ceiling Media Air Cleaner
F111 (Series 1,2)

FEATURES

• High Efficiency Particulate Air (HEPA) filter models are
99.97% efficient and the hospital grade particle filter
models are 95% efficient at 0.3 micron particles. Both
models are more efficient on particles smaller and
larger. There is also a 95% ASHRAE model.
• Circulates up to 1230 cfm.
• Designed to overcome the increase in air flow
resistance normally caused by filter loading.
• White or black color cover to complement the ceiling.
• CPZ™ module removes up to 95% of the space odors
for up to 24 months.
• READ AND SAVE THESE
INSTRUCTIONS
Application.........................................................................1
Features ............................................................................1
Specifications ....................................................................2
Ordering Information .........................................................2
Planning the Installation ....................................................3
Installation .........................................................................4
Operation...........................................................................6
Service ..............................................................................6
Parts List ...........................................................................8
Limited Two-Year Warranty ...............................................10
PRODUCT DATA
Contents
68-0198EF-4

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F111 Series 1

  • Page 1: Table Of Contents

    The Honeywell Trademark is used under license from Honeywell Intellectual Properties, inc. by Air-Pure Systems. Honeywell International Inc. makes no representations or warranties with...
  • Page 2: Specifications

    Ordering Information If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Commercial Air Products Distributor. 2. Air-Pure Systems. 16873 Fish Point Rd. SE Prior Lake, MN 55372 www.cleanairfacility.com...
  • Page 3: Planning The Installation

    If any questions should arise concerning determining the number of air cleaners needed for an area, consult your distributor or local Honeywell Commercial Air Cleaner Distributor. Table 3. Determining the Minimum Number of Air Cleaners Needed for a Space.
  • Page 4: Installation

    • literature. • latches (2) Make Opening (if Mounting in a Drop Ceiling) 1. Size the opening to fit the air cleaner cabinet as closely as possible. 2. Frame the opening to provide adequate support for the cabinet. The cabinet must fit snugly in the opening;...
  • Page 5 • Never rest the air cleaner on the T-bar. 5. Level the air cleaner. 6. Turn the air cleaner power on and check for proper operation for 2 to 3 minutes. There should be a smooth, powerful blower sound and air discharging from both ends of the air cleaner.
  • Page 6: Operation

    1. Slowly open the lid, supporting the lid so the filters do not fall out. 2. Remove the dirty prefilter. 3. Install the new prefilter in the air cleaner lid. Position the metal screen mesh so it is facing upward when the lid is closed.
  • Page 7 The impurities are collected until the adsorbents reach saturation. At saturation, the adsorbents emit a continuous strong pungent odor. If the air cleaner is turned off for 8 to 10 hours, there will a temporary odor when it is turned back on. If the odor persists for 30 minutes, it is time to replace the filters.
  • Page 8: Parts List

    F111 (SERIES 1,2) IN CEILING MEDIA AIR CLEANER PARTS LIST Refer to Fig. 8 and Table 4 for replacement part information. Fig. Reference No. CPZ™ sorbent module (requires 2)—used with only 95% HEPA or 95% ASHRAE particle filters Charcoal sorbent module (requires 2)—used with only 95% HEPA or 95% ASHRAE particle filters Zeolite sorbent module (requires 2)—used with only...
  • Page 9 Fig. 8. Exploded view of F111 (series 1,2) in Ceiling Media Air Cleaner components. F111 (SERIES 1,2) IN CEILING MEDIA AIR CLEANER CABINET ASSEMBLY SORBENT MEDIA MODULE (2 REQUIRED) BLOWER WHEEL MOTOR CAPACITOR MOTOR MEDIA FILTER PREFILTER LID ASSEMBLY WITH...
  • Page 10: Limited Two-Year Warranty

    LIMITED TWO-YEAR WARRANTY Air-Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service, for a period of two (2) years from the date of purchase by the original end-user. If at anytime during the warranty period the product is defective or malfunc- tions, Air-Pure Systems, through the distributor or dealer, from which the product was purchased, or through an authorized warranty repair station, shall at Air-Pure Systems option, replace or repair the defective product or component.

Table of Contents