00h
01h..FFh
3.3.10 SI – set iso standard
With this command you can switch the iso standard of the reader.
Input format:
Output (example):
Parameter:
PARAMETER
0
1
3.3.11 VSAVE – variables save
With the command VSAVE the following parameters are saved to the internal EEPROM:
2
AFI
, BD, BS, CE
Input format:
Output (example):
1
just available in the ISO 14443A standard
2
just available in the ISO 15693 standard
3.3.12 VS – variables show
With the command VS the reader shows the settings of the following parameters:
2
AFI
, BD, BS, CE
Input format:
Output (example):
--------------------------------------------------------------------------------20/45--------------------------------------------------------------------------------
limits the reading process duration of exactly one reading cycle
limits the reading process duration to maximum 1..256 times
TB
SI <SP> parameter <CR>
0 <CR>
FUNCTION
ISO 14443A
ISO 15693
1
, CID, CN, HID, KL, KM
VSAVE <CR>
ACK <CR>
1
, CID, CN, HID, KL, KM
VS <CR>
BD <SP> 0 <SP>
1
1
, KT
, LAA, LED, MC, MD, SF, SI, TOR, TSC
1
1
, KT
, LAA, LED, MC, MD, SF, SI, TOR, TSC