IF1C Fixed RFID Reader User Guide
Description
The maximum number of times the read algorithm is executed before
a response is returned to a Write command. Valid range is 1 to 254.
Default is 5.
In practice, this is the number of times an identified tag is written until
the Write is successful.
This setting is equivalent to the WRTRIES BRI attribute.
The maximum number of times the lock algorithm is executed before
a response is returned to a Lock command. Valid range is 1 to 254.
Default is 3.
This setting is equivalent to the LOCKTRIES BRI attribute.
The character used for separating fields in tag data. Choose from
space ( ), comma (,), colon (:), semicolon (;), tab, caret (^), or tilde (~).
Default is space ( ).
This setting is equivalent to the FIELDSEP BRI attribute.
Enables tag ID reporting after a Read, Write, or Lock command is
executed:
For ISO tags, the tag identifier corresponds to TAGID
For EPC tags, the identifier corresponds to EPCID
Default is enabled.
This setting is equivalent to the IDREPORT BRI attribute.
Enables a NOTAG message, which is sent when no tags are found
during execution of a Read, Write, or Lock command. Default is
enabled.
This setting is equivalent to the NOTAGRPT BRI attribute.
The timeout (in ms) for delays in tag reporting when the RFID reader
is in continuous read mode. Valid range is 0 to 65534. Default is 0.
This setting is equivalent to the RPTTIMEOUT BRI attribute.
Establishes whether to use the Timeout or Tries attributes. Default is
off.
This setting is equivalent to the TIMEOUTMODE BRI attribute.
The command session parameter to a corresponding EPCglobal
Class 1 Gen 2 air protocol command. Valid range is 0 to 3. Default is 3.
This setting is equivalent to the SESSION BRI attribute.
(EPCglobal Class 1 Gen 2 tags only) The initial Q parameter value
used by the Query command. Valid range is 1 to 254. Default is 4.
If you know there is only one tag in the field, set this attribute to 0 for
best performance.
This setting is equivalent to the INITIALQ BRI attribute.
The maximum number of times the reader attempts to initialize a tag.
Valid range is 1 to 254. Default is 1.
This setting is equivalent to the INITTRIES BRI attribute.
15