2. Using the RS232 interface of the reader ARE i2
3. Using the RS232 interface of the AMP 4/8
4. Using the RS232 interface of the reader ARE i2
5.2

Controlling via reader ARE i2 (mode 2)

In mode 2 the power supply and the data line of the AMP 4/8 is connected directly to the SAB cap of the
ARE i2.
There is a PC connection cable available with this wiring.
It is important not to change the SAB cap of the AMP 4/8 with the SAB cap of the ARE i2.
If you use your own cable be sure with the pin assignment of the AMP 4/8 (chapter 2.4.4.3) and the
ARE i2.
The typical sequence in mode 2 is as follows:
--------------------------------------------------------------------------------15/20--------------------------------------------------------------------------------
GT<CR> -> reading the transponder in the field of antenna 2
MP4<CR> ->switching to antenna channel 4
GT<CR> -> reading the transponder in the field of antenna 4
antenna 1
AEG
ID
AMP 4/8
antenna 2
.
Vcc
1
.
2
4
.
8
antenna 8
power supply
+
data line
between AMP and ARE i2
Figure 4: system overview controlling via reader ARE i2 (mode 2)
antenna connection
AEG
ID
ARE i2
L1
L2
L3
L4
L5
SAB cap
power supply (z.B PC connection
cable for ARE i2 und AMP 4/8)