Visual Signal Lamps; Instruction Set / Structure Of The Instruction Set; Generall - AEG AMP 4 Installation Manual

Antenna multiplexer
Table of Contents

Advertisement

3

Visual signal lamps

You can see the state of the AMP 4/8 on the lamps.
AEG
AMP4/8
Figure 1: visual signal lamps
4

Instruction set / structure of the instruction set

4.1

Generall

The command set described below defines the transfer of data on the serial interface.
The commands consist of a command code and optionally of a parameter value. Commands are ter-
minated by the control character <CR> (13h). The control character serves as command line termi-
nator.
Command codes and parameters, that means all letters and numerical values, are principally trans-
mitted as a sequence of ASCII characters (the value 255 (decimal) consequently as 32H, 35H,
35H; the command RST as 52H, 53H, 54H).
--------------------------------------------------------------------------------10/20--------------------------------------------------------------------------------
Vcc:
twinkles, if the processor works
ID
1, 2, 4, 8: show the active channel of the AMP 4/8 (binary)
examples:
LED 1:
LED 2:
Vcc
1
LED 2 + LED 1:
2
LED 4:
4
8
LED 4 + LED 1:
LED 4 + LED 2:
LED 4 + LED 2 + LED 1:
LED 8:
channel 1
channel 2
channel 3
channel 4
channel 5
channel 6
channel 7
channel 8