4.2 RUN and SETUP Modes

4.2.1 About SETUP and RUN Modes

RUN Mode:
This is a mode of performing an inspection. The AX40 starts in this mode when you turn it on
RUN mode, the AX40 accepts various kinds of signals including inspection start signals (START signal)
from the external device. In addition, in this mode, the inspection results can be output to the external
device according to the communication and output conditions. You cannot set or change the product type
or environmental data, etc. with the keypad.
SETUP Mode:
This is a mode of setting or changing all the options in the menu bar (TYPE, CHECKER, TOOL,
ENVIRONMENT, CARD, and INFO.). All the signals including the inspection start signal (START signal)
but excluding key emulation from the external device cannot be accepted. Press the A key on the keypad
to perform a test, but the results will not be output to the external device.
*1
The product types that are displayed when you turn the AX40 on are the ones that have been
selected before the device is turned off.
4.2.2 Switching between RUN Mode and SETUP Mode
Press the C key to switch between the two modes. (You can switch from SETUP mode to RUN mode
only if the SETUP window is not displayed.)
If you cannot switch the modes by pressing the C key, the "setting protection by password" function has
been set. In this case, keep pressing the C key for more than one second so that the "Password" window
is displayed. Enter your password to switch the modes.
See page 190 for protecting the setting data by password.