Timing Chart: Area Display = Yes
1.
Specify a number of the target checker to register that is assigned to IN 1- 7. (Input the data
more than 1 ms before FCT2 signal input)
2.
Make sure that READY signal is on and input a FCT2 signal.
(1) After READY signal is turned off, the re-registered area is displayed.
(2) After re-register area is displayed, STROB signal is turned on.
3.
Make sure that the ready signal is off and then turn the FCT2 signal off.
4.
Input the second FCT2 signal after checking the re-registered area on the screen monitor.
Re-registration is executed.
(1) After re-registration is completed, the ready signal is turned on.
(2) READY signal is turned off upon the READY signal ON.
5.
Make sure that READY signal is on (re-registration is completed) and then turn the FCT2
signal off.
The templates of the following checkers cannot be re-registered from the external device.
- Position Adjustment (Matching)
- Rotation Adjustment (Matching)
- Rotation Adjustment (Contour)
If the image cannot be re-registered or the image has no features, ERROR signal will be
output.