8.5 BACKUP RESTORE SYSTEM

8.5.1 Backup

You can use BACKUP RESTORE SYSTEM to back up the data on the CPU module.
Confirm the following before backing up the CPU data:
[1] The PADT is not connected to an ET.NET module.
[2] The hardware CPU RUN/STOP switch is set to RUN.
(1) From the BASE SYSTEM main menu, select Online and then Backup. If the communication type is
ET.NET, an error message indicating that the function cannot be used with ET.NET is displayed (Figure
8-50).
If the CPU mode of the PCs is RUN, a message appears asking you to confirm that the CPU mode can
be changed to STOP.

Figure 8-122 CPU stop confirmation message for backup function

Click OK to place the CPU in STOP mode.
If you click Cancel, a message appears indicating that the backup process will be canceled.
Click OK. You are returned to the BASE SYSTEM window.
As when replacing the CPU module, this message does not appear if the CPU module is already in
STOP mode.