Download Print this page

Honeywell MPA1C1 Installation Manual page 45

Access control unit

Advertisement

Basic Standalone Operation
Card Read / Door Lock Operation
Step 1. Present a card to a reader.
Step 2. The reader sends the card number to a reader input on
the panel.
Step 3. The panel searches its database and:
• If it is a valid card, then energize the door relay associated with
the reader input. The card is valid when it is in the card
database on the panel and the current time and date
conforms to the time zone associated with the card.
• If it is not a valid card, the door relay remains locked.
Door Egress (REX) / Door Lock / Door Status Operation
Step 1. Activate the door egress input (REX).
Step 2. The panel energizes the door relay associated with the
particular door egress input for a default time of 10
seconds.
Step 3. If the door status goes from close to open to close again
during the 10 second door open period, the door relay
will be immediately de-energized.
Maintenance
Perform the following maintenance on the MPA1C1 installation:
• Change any backup battery every two to two-and-a-half years.
• Oil the lock once per year.
44

Advertisement

loading

This manual is also suitable for:

Mpa1encp