Wiring Electrical Door Lock
Wire door strikes and magnetic locks.
Wiring Door Strikes
• Follow these steps to wire door strike to the Controller Board:
• Use the following figure to locate the door strike terminals on the
controller and to wire the door strike lock according to the power
supply used.
• Be sure to use the S4 suppressor kits as shown below. The 12VDC
OUT is limited to 500mA. In this case the controller may be powered
using PoE or external 12VDC.
• The DR LCK SWITCHED GROUND (SW GND) door operation can be
set in the web user interface and host software as FAIL SAFE, or
FAIL SECURE.
• If the door operation is set for FAIL SECURE a door strike that locks
without power can be connected
• If the door operation is set for FAIL SAFE the door strike that
releases without power can be connected
Wiring an Access Control Door Strike
Note: S4 Suppressor kits are not evaluated by UL294 and CAN/
ULC60839-11-1.