Program
Program Name
No.
20-13-10
Class of Service Options (Supplementary Serv-
ice) - Barge-In Monitor
24-02-07
System Options for Transfer - Trunk-to-Trunk
Transfer Release Warning Tone
24-02-10
System Options for Transfer - Disconnect Trunk-
to-Trunk
25-07-07
System Timers for VRS/DISA - Long Conversa-
tion Warning Tone Time
25-07-08
System Timers for VRS/DISA - Long Conversa-
tion Disconnect Time
Method B - Tandem Trunking with Transfer Key
Program
Program Name
No.
14-01-04
Basic Trunk Data Setup - Transmit Gain Level for
Conference and Transfer Calls
14-01-05
Basic Trunk Data Setup - Receive Gain Level for
Conference and Transfer Calls
14-01-13
Basic Trunk Data Setup - Trunk-to-Trunk Trans-
fer
14-02-12
Analog Trunk Data Setup - Detect Network Dis-
connect Signal
15-07-01
Programmable Function Keys
20-06-01
Class of Service for Extensions - Class of Serv-
ice for Extensions
20-07-11
Class of Service Options (Administrator Level) -
Forced Trunk Disconnect (analog trunk only)
20-11-14
Class of Service Options (Hold/Transfer Service)
- Trunk-to-Trunk Transfer Restriction
20-11-21
Class of Service Options (Hold/Transfer Service)
- Restriction for Tandem Trunking on Hang Up
20-13-10
Class of Service Options (Supplementary Serv-
ice) - Barge-In Monitor
24-02-07
System Options for Transfer - Trunk-to-Trunk
Transfer Release Warning Tone
24-02-10
System Options for Transfer - Disconnect Trunk-
to-Trunk
25-07-07
System Timers for VRS/DISA - Long Conversa-
tion Warning Tone Time
25-07-08
System Timers for VRS/DISA - Long Conversa-
tion Disconnect Time
81-01-03
CO Initial Data Setup - Clear Signal (Open Loop)
Detection Time
Features and Specifications Manual
Input Data
0 = Speech
1 = Monitor
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
Input Data
1 ~ 57
(-15.5 dB ~ +12.5 dB in 0.5 dB
intervals)
1 ~ 57
(-15.5 dB ~ +12.5 dB in 0.5 dB
intervals)
0 = Disable (No)
1 = Enable (Yes)
0 = Disable (No)
1 = Enable (Yes)
-
1 ~ 15
0 = Off
1 = On
0 = Off
1 = On
0 = Allow
1 = Deny
0 = Speech
1 = Monitor
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
1 ~ 255
(5 ~ 1275 ms)
SL2100
Default
COS 01 ~ 15 = 0
1800
0
1800
30
Default
32 (0 dB)
32 (0 dB)
1
0
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
Extension 101 is Class
15 and other Extension
are Class 1
COS1 ~ 14/COS15 = 1
COS 01 ~ 15 = 0
COS 01 ~ 15 = 0
COS 01 ~ 15 = 0
1800
0
1800
30
62 (310 ms)
1-819
T