NEC SL2100 Features And Specifications Manual page 770

Hide thumbs Also See for SL2100:
Table of Contents

Advertisement

SL2100
Program
No.
11-10-47
Service Code Setup (for System Administrator) -
Warning Message Setting
11-10-48
Service Code Setup (for System Administrator) -
Auto Dial Setting for Security Sensor
11-12-62
Service Code Setup (for Service Access) - Secur-
ity Sensor Reset
11-12-63
Service Code Setup (for Service Access) - Watch
Mode Start
11-12-64
Service Code Setup (for Service Access) - Secur-
ity Sensor Mode Start
15-07
Programmable Function Keys
S
20-44-01
Watch Mode Setup - Internal Paging Group for
Watch Message
20-44-02
Watch Mode Setup - External Paging Group for
Watch Message
20-44-03
Watch Mode Setup - VRS Message for Watch
Mode
20-44-04
Watch Mode Setup - Interval Timer for Watch
Message
20-46-01
Security Sensor Setup - Sensor Mode
20-46-02
Security Sensor Setup - Internal Paging Group
for Warning Message
20-46-03
Security Sensor Setup - External Paging Group
for Warning Message
20-46-04
Security Sensor Setup - VRS Message for Warn-
ing
20-46-05
Security Sensor Setup - Auto Dial Number Area
Setting
20-46-06
Security Sensor Setup - VRS Message for An-
swer
20-46-07
Security Sensor Setup - Auto Dial Wait Timer
20-46-08
Security Sensor Setup - Time of Repeat Auto Di-
al
20-46-09
Security Sensor Setup - Auto Dial Calling Time
20-46-10
Security Sensor Setup - Monitored Terminal
20-46-11
Security Sensor Setup - Interval of Auto Dial
20-47-01
Time pattern setting for Watch Mode - Watch
Mode Time Pattern
20-48-01
Time pattern setting for Security Sensor - Secur-
ity Sensor Time Pattern
20-55-01
Delay Timer for Security Sensor - Sensor delay
timer
35-02-22
SMDR Output Options - Security Auto Dialing
82-21-01
Sensor Setup - Sensor Type
1-756
Program Name
Input Data
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 8 digit
*
0~9,
, # Maximum of 8 digit
*
-
0 ~ 50
0 ~ 8
0 ~ 100
0 ~ 60
0 = Off
1 = On
0 ~ 50
0 ~ 3
0 ~ 100
0 ~ 999
0 ~ 100
0 ~ 64800
0 ~ 255
0, 1 ~ 3600
0 = No Auto Dial
Extension Number (Up to 8 dig-
its)
0 ~ 3600
0 = Off
1 = On
0 = Off
1 = On
0 ~ 3600 (seconds)
0 = Sensor will start immediately
0 = No Output
1 = Output
0 = Close Detect
1 = Open Detect
ISSUE 1.0
Default
615
617
716
717
719
Refer to the program-
ming manual for the
default values and for
all other available op-
tions in this command.
0
0
0
0
0
0
0
0
0
0
30
3
30
No Setting
0
0
0
60
1
0
Security

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents