Digital Outputs

Digital Outputs (Standard)

The digital outputs are compatible with digital inputs of types 1, 2 and 3
(IEC 61131).
Fig. 8-30:
Symbol
Data
Output voltage ON
1)
Output current OFF
Output current ON
Sum of output currents
2)
■ 4 outputs
■ 8 outputs
Allowed energy content of con‐
nected inductive loads
3) 4)
■ f < 0.5 Hz
■ f < 2 Hz
Control delay
Short circuit protection
Overload protection
1)
U
: Supply voltage
ext
2)
When several outputs supply current simultaneously, the maxi‐
mum allowed total current of these outputs must be taken into
account. According to the number of outputs, the total current
must be related to to 4 or 8 outputs.
3)
In the case of inductive loads with a greater energy content, an
external free-wheeling arm must be installed. The effective ter‐
minal voltage must be < 25 V.
4)
The maximum energy content depends on the switching fre‐
quency f of the outputs
5)
Applies to optional I/O extension DA
Tab. 8-31:
Digital Outputs
The digital outputs have been realized with high-side
switches. This means that these outputs only can actively
supply current.
The energy absorption capacity of the outputs is used to limit
voltage peaks caused when inductive loads are switched off.
Limit voltage peaks by using free-wheeling diodes directly at
the relay coil.
Bosch Rexroth AG
Technical data - functions
Unit
Min.
V
U
- 1
ext
mA
mA
mA
mJ
µs
Present
Present
119/143
Max.
U
ext
0,05
500
■ 1000
■ 2000
■ 500
■ 200
800
200
5)