Pb - Profibus - Bosch Rexroth IndraDrive CSB02 Project Planning Manual

Control sections
Table of Contents

Advertisement

DOK-INDRV*-CXX02******-PR03-EN-P
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
8.4

PB - PROFIBUS

Signal Specification
Diagnostic Displays
Signal
+5V
Repeater supply
Repeater control signal
Receive/transmit data
Tab. 8-22:
Signal Specification
NOTICE
Do not short-circuit the output.
Do not exceed the maximum current.
For the significance of the diagnostic displays, see firmware documentation.
Bosch Rexroth AG
Technical data - functions
Specification
+5 V (±10%)
Max. 75 mA
TTL-compatible:
1: Transmit
0: Receive
Output resistance: 350R
V
≤ 0.8 V at I
≤ 2 mA
OL
OL
V
≥ 3.5 V at I
≤ 1 mA
OH
OH
EIA-RS485 standard
Danger of destroying output
"+5V repeater supply" by overload!
111/143

Advertisement

Table of Contents
loading

Table of Contents