XYR 6000 Pressure continued ..
 Name
 Description
DLMO_RADIO_TRANSMIT_POWER
Radio maximum transmit level.
DLMO_CHANNEL_DIAG
Channel diagnostics.
DLMO_CHANNEL_DIAG.CHANNEL
Channel number.
Percentage of transmissions for this channel that did 
DLMO_CHANNEL_DIAG.NO_ACK
not receive an ACK or NACK.
Percentage of transmissions for this channel aborted 
due to CCA backoff.
DLMO_CHANNEL_DIAG.BACKOFF
DLMO_NEIGHBOR_DIAG
Neighbor diagnostics.
DLMO_NEIGHBOR_DIAG.NEIGHBOR
Neighbor name.
RSSI (Received Signal Strength Indicator) with respect 
DLMO_NEIGHBOR_DIAG.RSSI
to this neighbor.
RSQI (Received Signal Quality Indicator) with respect to 
DLMO_NEIGHBOR_DIAG.RSQI
this neighbor.
Number of failed unicast transmissions to this 
DLMO_NEIGHBOR_DIAG.TX_FAILED
neighbor.
Number of transmissions to this neighbor that were 
DLMO_NEIGHBOR_DIAG.TX_BACKOFF
aborted due to CCA backoff.
DLMO_NEIGHBOR_DIAG.TX_NACK
Number of NACKs received from this neighbor.
Standard deviation of clock corrections with respect to 
DLMO_NEIGHBOR_DIAG.CLOCK_SIGMA
this neighbor.
STAT_PUBSEND
Publications from WDM to field device application.
STAT_PUBRECV
Publications from field device application to WDM.
STAT_READREQSEND
Read requests from WDM to field device application.
STAT_READREQRECV
Read requests from field device application to WDM.
Read request timeouts between WDM and field device 
STAT_READREQTIMEOUT
application.
STAT_READRSPSEND
Read response from WDM to field device application. Uint32
STAT_READRSPRECV
Read response from field device application to WDM. Uint32
Read response timeouts between WDM and field 
STAT_READRSPTIMEOUT
device application.
STAT_WRITEREQSEND
Write request from WDM to field device application.
STAT_WRITEREQRECV
Write requests from field device application to WDM. Uint32
Write request timeouts between WDM and field 
STAT_WRITEREQTIMEOUT
device application.
60
Data Type
Int8
ChannelDiag[16]
Uint8
Uint8
Uint8
NeighborDiag[8]
VisibleString
Int16
Uint8
Uint16
Uint16
Uint16
Int16
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
OneWireless XYR 6000 ISA100.11a Compliant Pressure Transmitter User's Manual
Data Size Access
Class
Enum Value
1 Read Only
Static
3 Read Only
Dynamic
1 Read Only
Dynamic
1 Read Only
Dynamic
1 Read Only
Dynamic
27 Read Only
Dynamic
16 Read Only
Dynamic
2 Read Only
Dynamic
1 Read Only
Dynamic
2 Read Only
Dynamic
2 Read Only
Dynamic
2 Read Only
Dynamic
2 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
4 Read Only
Dynamic
Enum Description