Setting The Epr - Method 2 - GE ADTS552F User Manual

Air data test sets
Hide thumbs Also See for ADTS552F:
Table of Contents

Advertisement

E
P
R
(EPR)
NGINE
RESSURE
ATIO
Figure 3-31: EPR Control Screen (Method1)
3)
Touch the "Aim" value (2). A numbered keypad opens.
4)
Enter the desired "Aim" value and touch the "tick" icon. The numbered keypad closes and
the previously entered value appears in the "IN" display.
5)
Touch the "Aim" value (3). A numbered keypad opens.
6)
Enter the desired "Aim" value and touch the "tick" icon. The numbered keypad closes and
the previously entered value appears in the "EPR" display.
Wait for the controller to achieve the EPR aim value and inlet pressure. The outlet pressure has
now been set based on the inlet pressure and EPR value.

Setting the EPR - method 2

EPR testing can also be performed by specifying the actual INLET and OUTLET values.
1)
On the "Dashboard", select "EPR". The EPR control screen appears.
2)
On the EPR control screen, set the toggle control (1) for Direct control of Inlet and Outlet
pressure.