CLIF-CBUSLC INTERFACE – INSTALLATION & COMMISSIONING INSTRUCTIONS

SAFETY INFORMATION

General Safety Information

When performing any work, all instructions given by the
manufacturer and in particular the safety instructions
provided in these Installation and Commissioning
Instructions are to be observed. Make sure that the local
standards and regulations are observed at all times.
The CLIF-CBUSLC Interface and C-Bus controllers may be
installed and mounted only by authorized and trained
personnel.
If the device housing is damaged or missing, immediately
disconnect it from any power.
If the device is broken or defective, do not attempt to repair
it yourself; rather, return it to the manufacturer.
It is recommended that devices be kept at room tem-
perature for at least 24 hours before applying power. This
is to allow any condensation resulting from low shipping /
storage temperatures to evaporate.
The CLIF-CBUSLC must be installed in such a manner
(e.g., in a lockable cabinet) as to ensure that uncertified
persons have no access to the terminals.
In the case of vertical mounting on DIN rails, the CLIF-
CBUSLC Interface should be secured in place using a
commercially-available stopper.
If the CLIF-CBUSLC is modified in any way, except by the
manufacturer, all warranties concerning operation and
safety are invalidated.
Rules regarding electrostatic discharge should be followed.
Use only accessory equipment which comes from or has
been approved by Honeywell.

Information as per EN 60730

Purpose
The purpose of the device is: OPERATING CONTROL. The
CLIF-CBUSLC is an interface device intended for HVAC in
home (residential, commercial, and light-industrial)
environments.
Construction
The CLIF-CBUSLC is an independently mounted electronic
control unit with fixed wiring.
Mounting Method
The CLIF-CBUSLC is suitable for mounting as follows:
in cabinets;
in fuse boxes conforming with standard DIN43880, and
having a slot height of max. 45 mm;
on walls (using accessory MVC-80-AC1).
EN1Z-1026GE51 R0417
Table 1. Information as per EN 60730
Shock protection
Pollution degree
Installation
Software class
Ball-pressure test
temperature

WEEE Directive

WEEE: Waste Electrical and Electronic
Equipment Directive
At the end of the product life, dispose of
the packaging and product in an
appropriate recycling center.
Do not dispose of the device with the
usual domestic refuse.
Do not burn the device.

Standards, Approvals, etc.

Degree of Protection: IP20 (mounted on walls, with two
accessory MVC-80-AC1 covers)
Refer to Code of Practice standards IEC 61000-5-1 and -2
for guidance.
The device complies with Ethernet Protocol versions IEEEC
802.3.

RELATED TECHNICAL LITERATURE

Table 2. Related Technical Literature
Title
CLIF-CBUSLC – Product Data
CLIF-CBUSLC – Mounting Instructions
CentraLine NX C-Bus Driver – User Guide
IF-LON2 – Product Data & Mounting Instr.
General Security Best Practices
2
Class II
2
Class 3
Class A
housing parts >75 °C
terminals >125 °C
Product
Literature no.
EN0Z-1026GE51
MU1Z-1026GE51
EN2Z-1021GE51
MU1Z-0545GE51
EN0Z-1017GE51