The examples of data setting is described below.
(1)
Example in the case that station number 300 is to be assigned to LEN000 and station number 301 to
LEN001 by CM10.
STEP 1
Set CAT mode.
STEP 2
Press
STEP 3
Enter "10" (Command Code).
STEP 4
Press
STEP 5
Enter "000" (LEN).
STEP 6
Press
STEP 7
Enter "300" (Station Number).
STEP 8
Press
STEP 9
Press
STEP 10
Press
STEP 11
Enter "301" (Station Number).
STEP 12
Press
STEP 13
Press
STEP 14
Lift handset, then replace it.
NOTE 1:
When no data exists, "NONE" is displayed. And when data exists, that data is displayed.
NOTE 2:
This
operation is for confirming the data assignment. You can omit this step.
DE
Example of CAT Operation
ST .
DE .
DE .
EXE .
DE .
S .
EXE .
DE .
CHAPTER 1 HOW TO USE CAT
(Display)
CAT MODE
COMMAND =
COMMAND = 10
10 >
10 > 000
10 > 000: NONE−
10 > 000: NONE−300
OK
10 > 000: 300 −
10 > 001: NONE
10 > 001: NONE−301
OK
10 > 001: 301
– 17 –
CAT OPERATION
NOTE 1
NOTE 2
NOTE 1
NOTE 2
NWA-008844-001 Rev.5.0
91ch1001.fm